Security Resilience

CVE-2024-0313

Published
14 March 2024
Modified
15 April 2026
CVSS Score v3.1 5.5
Click a component to see what it means
Raw vectorCVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N
EPSS Score 0.0018 7th percentile
Risk Priority 41 floored blend · peak EPSS

CVSS and EPSS are reproduced from their sources (NVD, FIRST EPSS). Risk Priority is our own derived reading, not an NVD score.

Summary

CVE-2024-0313 is a medium-severity Always-Incorrect Control Flow Implementation (CWE-670) vulnerability in Trellix (inferred from references). Its CVSS base score is 5.5 (Medium).

Operationally, ranked at the 7th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

The strongest mitigations our analysis identified map to SA-11 (Developer Testing and Evaluation) and SA-15 (Development Process, Standards, and Tools) — see the control section below for these in your framework.

EU & UK References

Vulnerability Data

A malicious insider exploiting this vulnerability can circumvent existing security controls put in place by the organization. On the contrary, if the victim is legitimately using the temporary bypass to reach out to the Internet for retrieving application and system…

more

updates, a remote device could target it and undo the bypass, thereby denying the victim access to the update service, causing it to fail.

CWE(s)

Related Threats

CVEs Like This One

CVE-2026-12321Shared CWE-670
CVE-2026-40942Shared CWE-670
CVE-2026-56328Shared CWE-670
CVE-2023-20915Shared CWE-670
CVE-2024-47763Shared CWE-670
CVE-2024-5659Shared CWE-670
CVE-2023-23623Shared CWE-670
CVE-2026-40960Shared CWE-670
CVE-2026-40719Shared CWE-670
CVE-2024-53269Shared CWE-670

Affected Assets

Trellix
—
inferred from references and description; NVD did not file a CPE for this CVE

Mitigating Controls

Mitigating Controls (NIST 800-53 r5) AI

Developer testing and evaluation at post-design stages directly exercises control-flow paths and reveals mismatches between implemented and intended behavior.

Requiring a documented development process and supporting tools reduces the chance that incorrect control-flow logic is introduced in the first place.

Flaw identification and remediation processes can locate and correct control-flow errors once they manifest as incorrect runtime behavior.

Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.

blocks

A.8.25 mandates an SDLC process that includes security requirements, checkpoints, secure coding guidelines, testing and developer training, which reaches a slice of control-flow defects but leaves most implementation bugs untouched without perfect enforcement at every checkpoint.

prevents

Secure coding standards and reviews directly target flawed control-flow implementations.

finds

Security testing in development and acceptance can detect paths that deviate from intended logic.

blocks

A.8.32 mandates a formal process for planning, authorizing, testing and documenting changes but does not itself inspect, correct or block the incorrect control-flow logic that CWE-670 describes; the defect can still be introduced and exploited if the developer writes it and the process accepts it.

Hardening callouts derived

DISA STIG baselines are authored against specific weaknesses. Where this CVE cites a broad weakness class, the mapping is not asserted at that abstraction (owner ruling, 2026-09-25: grade only at Base and below), so no rule is shown here rather than a rule shown against the wrong grain.

  • No fine-grained STIG row for CWE-670, a class-level weakness, and none of its children carries one either.

References