CVE-2024-11158

Rockwellautomation Arena ≤ 16.20.00

Published
05 December 2024
Modified
18 April 2025
Patch / advisory
CVSS Score v4 8.5
Click a component to see what it means
Raw vectorCVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS Score 0.0023 13th percentile
Risk Priority 55 floored blend · peak EPSS

CVSS and EPSS are reproduced from their sources (NVD, FIRST EPSS). Risk Priority is our own derived reading, not an NVD score.

Summary

CVE-2024-11158 is a high-severity Improper Initialization (CWE-665) vulnerability in Rockwellautomation Arena. Its CVSS base score is 8.5 (High).

Operationally, ranked at the 13th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

The strongest mitigations our analysis identified map to SA-11 (Developer Testing and Evaluation) and SA-8 (Security and Privacy Engineering Principles) — see the control section below for these in your framework.

EU & UK References

Vulnerability Data

An “uninitialized variable” code execution vulnerability exists in the Rockwell Automation Arena® that could allow a threat actor to craft a DOE file and force the software to access a variable before it being initialized. If exploited, a threat actor…

more

could leverage this vulnerability to execute arbitrary code. To exploit this vulnerability, a legitimate user must execute the malicious code crafted by the threat actor.

CWE(s)

Related Threats

CVEs Like This One

CVE-2024-21918Same product: Rockwellautomation Arena
CVE-2025-6376Same product: Rockwellautomation Arena
CVE-2025-3287Same product: Rockwellautomation Arena
CVE-2023-29460Same product: Rockwellautomation Arena
CVE-2024-21920Same product: Rockwellautomation Arena
CVE-2025-7032Same product: Rockwellautomation Arena
CVE-2024-12130Same product: Rockwellautomation Arena
CVE-2025-3286Same product: Rockwellautomation Arena
CVE-2025-7033Same product: Rockwellautomation Arena
CVE-2026-8313Same product: Rockwellautomation Arena

Affected Assets

rockwellautomation
arena
≤ 16.20.00

Mitigating Controls

Mitigating Controls (NIST 800-53 r5) AI

Developer testing and evaluation directly exercises initialization paths and can reveal missing or incorrect resource setup.

Engineering principles applied during design and implementation can require explicit initialization to a known state.

Requiring the system to fail to a known state structurally reduces the chance that uninitialized resources remain reachable.

Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.

blocks

A.8.25 mandates security requirements, checkpoints, secure coding, testing and developer capability in the SDLC which reaches improper initialization as a design/coding defect, but leaves a bounded remainder (e.g. initialization of third-party components or libraries chosen in procurement, and post-deployment configuration defaults).

blocks

A.8.27 mandates security-by-design principles (least privilege, default-deny, fail-securely, distrust-external-input, hardening) plus explicit design reviews that can catch and block many uninitialized-resource cases before they ship, but leaves a bounded remainder (e.g. vendor libraries, runtime-initialization bugs, or post-review code changes) that can still be present and exploitable.

prevents

Secure coding standards explicitly forbid uninitialized variables and mandate proper resource initialization before use.

finds

Security testing can detect uninitialized variables but does not itself enforce initialization practices.

blocks

defining, enforcing, and monitoring secure configuration templates (including defaults, disabled services, changed vendor passwords, minimized privileges) directly stops most improper-initialization cases from being exploitable; the bounded remainder is initialization logic inside custom application code that no configuration template reaches

Hardening callouts derived

DISA STIG baselines are authored against specific weaknesses. Where this CVE cites a broad weakness class, the mapping is not asserted at that abstraction (owner ruling, 2026-09-25: grade only at Base and below), so no rule is shown here rather than a rule shown against the wrong grain.

  • No fine-grained STIG row for CWE-665, a class-level weakness. Rules are authored against its narrower children: CWE-770.

References