Cyber Resilience

CVE-2025-11925

Critical

Published: 17 October 2025

Published
17 October 2025
Modified
07 November 2025
KEV Added
Patch
CVSS Score v4 10.0 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS Score 0.0003 9.0th percentile
Risk Priority 20 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2025-11925 is a critical-severity Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability in Azure-Access Blu-Ic2 Firmware. Its CVSS base score is 10.0 (Critical).

Operationally, ranked at the 9.0th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

EU & UK References

Vulnerability details

Incorrect Content-Type header in one of the APIs (`text/html` instead of `application/json`) replies may potentially allow injection of HTML/JavaScript into reply.This issue affects BLU-IC2: through 1.19.5; BLU-IC4: through 1.19.5.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

azure-access
blu-ic2 firmware
≤ 1.20
azure-access
blu-ic4 firmware
≤ 1.20

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-754

Requires detection and response to audit logging failures as an unusual or exceptional condition.

addresses: CWE-754

Implements detection of unusual or exceptional conditions followed by safe mode entry, reducing the window for exploitation of unchecked conditions.

addresses: CWE-754

Training ensures users perform required checks for unusual or exceptional conditions as part of contingency roles, limiting attacker leverage from skipped validations.

addresses: CWE-754

IR testing directly validates checks for unusual or exceptional conditions that could indicate security incidents.

addresses: CWE-754

Requires ongoing monitoring of organization-defined metrics and analysis, enabling checks for unusual or exceptional conditions.

addresses: CWE-754

Security testing routinely checks for unusual or exceptional inputs/conditions, identifying missing validation steps that flaw remediation then resolves.

addresses: CWE-754

Requires detection of unusual conditions followed by a controlled transition to the defined failure state.

addresses: CWE-754

MTTF determination forces explicit checks for conditions that precede predictable component failure.