CVE-2025-20271
Raw vector
CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:HSummary
CVE-2025-20271 is a high-severity Use of Uninitialized Variable (CWE-457) vulnerability in Cisco AnyConnect VPN (inferred from references). Its CVSS base score is 8.6 (High).
Operationally, ranked at the 41th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.
The strongest mitigations our analysis identified map to SA-11 (Developer Testing and Evaluation) and SA-15 (Development Process, Standards, and Tools) — see the control section below for these in your framework.
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2025-18656
Vulnerability Data
A vulnerability in the Cisco AnyConnect VPN server of Cisco Meraki MX and Cisco Meraki Z Series Teleworker Gateway devices could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition in the Cisco AnyConnect service on…
more
an affected device. This vulnerability is due to variable initialization errors when an SSL VPN session is established. An attacker could exploit this vulnerability by sending a sequence of crafted HTTPS requests to an affected device. A successful exploit could allow the attacker to cause the Cisco AnyConnect VPN server to restart, resulting in the failure of all established SSL VPN sessions and forcing remote users to initiate a new VPN connection and re-authenticate. A sustained attack could prevent new SSL VPN connections from being established, effectively making the Cisco AnyConnect VPN service unavailable for all legitimate users.
- CWE(s)
Related Threats
CVEs Like This One
Affected Assets
Mitigating Controls
Mitigating Controls (NIST 800-53 r5) AI
Developer testing and static analysis directly find uses of uninitialized variables before deployment.
Documented development standards and tools can enforce initialization requirements in code.
Engineering principles can mandate explicit variable initialization to avoid uninitialized use.
Mitigating Controls (NIST CSF 2.0) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.
Secure SDLC practices directly catch uninitialized-variable defects via static analysis and code review while the control encompasses many additional development controls.
Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.
Security testing can detect uninitialized-variable bugs, but the control is broader.
Secure development life cycle mandates practices that reduce uninitialized-variable defects.
Application security requirements can specify initialization rules, but the control itself does not directly address the weakness.
Secure coding explicitly requires variable initialization and static-analysis checks.
Secure architecture principles encourage defensive coding that can mitigate uninitialized variables.