CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XSummary
CVE-2025-24811 is a high-severity Improper Resource Shutdown or Release (CWE-404) vulnerability in Siemens (inferred from references). Its CVSS base score is 8.7 (High).
Operationally, exploitation aligns with the MITRE ATT&CK technique Exploitation for Privilege Escalation (T1068); ranked at the 45th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.
The strongest mitigations our analysis identified map to SA-11 (Developer Testing and Evaluation) and SA-8 (Security and Privacy Engineering Principles) — see the control section below for these in your framework.
Deeper analysis AI-assisted summary
Synthesised by an AI model from the NVD description and linked references — a reading aid, not an authoritative source.
CVE-2025-24811 is a vulnerability affecting numerous models of SIMATIC S7-1200 CPUs, including the CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0), and similar variants up to CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0), as well as multiple SIPLUS S7-1200 CPU models such as SIPLUS CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0) and others. These programmable logic controllers (PLCs) from Siemens do not correctly process certain specially crafted packets sent to port 80/tcp.
An unauthenticated attacker with network access to the affected device can exploit this vulnerability by sending the crafted packets, resulting in a denial-of-service condition that disrupts device operation. The issue carries a CVSS v3.1 base score of 7.5 (AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H) and is associated with CWE-404.
Siemens has published Security Advisory SSA-224824, available at https://cert-portal.siemens.com/productcert/html/ssa-224824.html, which provides details on mitigation and patching for this vulnerability.
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2025-3951
Vulnerability Data
A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0), SIMATIC S7-1200 CPU 1212C…
more
DC/DC/Rly (6ES7212-1HE40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0). Affected devices do not process correctly certain special crafted packets sent to port 80/tcp, which could allow an unauthenticated attacker to cause a denial of service in the device.
- CWE(s)
Related Threats
MITRE ATT&CK Enterprise Techniques
CVEs Like This One
Affected Assets
Mitigating Controls
Mitigating Controls (NIST 800-53 r5) AI
Developer testing and evaluation can discover missing or incorrect resource releases after code is written.
Engineering principles can require explicit resource acquisition/release patterns that stop improper shutdown from being introduced.
Priority-based resource allocation limits the blast radius when released resources are not returned to the pool.
Mitigating Controls (NIST CSF 2.0) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.
Secure SDLC practices directly include coding standards for correct resource allocation and release.
Runtime monitoring can detect resource exhaustion caused by improper shutdown or release.
Lifecycle management of assets can encompass proper resource release at end-of-life or shutdown.
Capacity management helps surface leaks from unreleased resources but does not prevent the coding flaw.
Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.
Including restart, recovery and media-handling instructions reduces the likelihood that resources or sensitive data will be left in an exposed or improperly released state after a failure.