CVE-2026-6984
Raw vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XSummary
CVE-2026-6984 is a low-severity Incomplete Filtering of Special Elements (CWE-791) vulnerability. Its CVSS base score is 2.0 (Low).
Operationally, exploitation aligns with the MITRE ATT&CK technique Template Injection (T1221); ranked at the 22th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.
The strongest mitigations our analysis identified map to SA-11 (Developer Testing and Evaluation) and SI-10 (Information Input Validation) — see the control section below for these in your framework.
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2026-25660
Vulnerability Data
A security flaw has been discovered in AstrBotDevs AstrBot up to 4.22.1. This affects the function create_template of the file astrbot/dashboard/routes/t2i.py of the component Dashboard API. The manipulation results in improper neutralization of special elements used in a template engine.…
more
The attack can be executed remotely. The exploit has been released to the public and may be used for attacks. The project was informed of the problem early through an issue report but has not responded yet.
- CWE(s)
Related Threats
MITRE ATT&CK Enterprise Techniques
CVEs Like This One
Affected Assets
Mitigating Controls
Control response
—
—
—
V1.3.2V1.3.7V1.3.10
Mitigating Controls (NIST 800-53 r5) AI
Developer testing and static analysis can discover missing neutralization of template directives.
Input validation directly requires complete filtering of special elements on received data before further processing or forwarding.
Security engineering principles require use of safe templating APIs and proper escaping of external input.
Mitigating Controls (NIST CSF 2.0) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.
Secure SDLC practices directly require complete input filtering and sanitization to prevent this weakness.
Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.
Security testing in development and acceptance can detect incomplete filtering but does not itself implement the filtering.
Secure development life cycle processes include validation activities that reduce the likelihood of CWE-791 but do not specify the control itself.
Application security requirements explicitly call for input validation and sanitization that directly mitigates incomplete special-element filtering.
Secure system architecture and engineering principles require defensive design patterns that prevent unfiltered data from reaching downstream components.
Secure coding standards mandate complete filtering and escaping of special elements, directly eliminating CWE-791.