CVE-2026-9143
Ni Instrumentstudio ≤ 2025
Raw vector
CVSS:4.0/AV:N/AC:H/AT:N/PR:N/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XSummary
CVE-2026-9143 is a medium-severity Incorrect Conversion between Numeric Types (CWE-681) vulnerability in Ni Instrumentstudio. Its CVSS base score is 6.3 (Medium).
Operationally, exploitation aligns with the MITRE ATT&CK technique Exploitation for Privilege Escalation (T1068); ranked at the 8th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.
The strongest mitigations our analysis identified map to SA-11 (Developer Testing and Evaluation) and SA-8 (Security and Privacy Engineering Principles) — see the control section below for these in your framework.
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2026-38032
Vulnerability Data
There is an incorrect conversion between numeric types vulnerability in NI grpc-device due to missing range checks in CodeGen. This may silently discard high bits if a size value exceeded the target type's range. This affects NI grpc-device 2.17.0 and…
more
prior versions.
- CWE(s)
Related Threats
MITRE ATT&CK Enterprise Techniques
CVEs Like This One
Affected Assets
Mitigating Controls
Mitigating Controls (NIST 800-53 r5) AI
Developer testing and evaluation can discover incorrect numeric conversions through targeted test cases.
Engineering principles can mandate safe numeric handling and range checks that structurally avoid bad conversions.
Input validation directly stops malformed or out-of-range numeric values from reaching conversion logic.
Mitigating Controls (NIST CSF 2.0) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.
Secure SDLC practices directly require code reviews, static analysis, and developer training that catch and prevent numeric type-conversion errors.
Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.
Security testing can detect numeric conversion defects before release.
Secure development lifecycle includes type-safety and conversion checks that reduce numeric truncation risks.
Application security requirements can mandate safe numeric handling and range validation.
Secure architecture principles promote strong typing and safe conversion practices.
Secure coding standards directly address correct numeric type conversions and overflow checks.