Cyber Resilience

CVE-2023-22610

Critical

Published: 31 January 2023

Published
31 January 2023
Modified
21 November 2024
KEV Added
Patch
CVSS Score v3.1 9.1 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H
EPSS Score 0.0049 65.9th percentile
Risk Priority 18 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2023-22610 is a critical-severity Incorrect Authorization (CWE-863) vulnerability in Schneider-Electric Ecostruxure Geo Scada Expert 2019. Its CVSS base score is 9.1 (Critical).

Operationally, ranked in the top 34.1% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.

EU & UK References

Vulnerability details

A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of Service against the Geo SCADA server when specific messages are sent to the server over the database server TCP port.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

schneider-electric
ecostruxure geo scada expert 2019
81.7268.1, 81.7322.1, 81.7429.2, 81.7457.1, 81.7488.1
schneider-electric
ecostruxure geo scada expert 2020
83.7551.1, 83.7578.1, 83.7613.1, 83.7641.1, 83.7692.1
schneider-electric
ecostruxure geo scada expert 2021
84.8027.1, 84.8108.1, 84.8120.1, 84.8158.1, 84.8182.1

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-863

Periodic review and update of procedures reduces incorrect authorization implementations over time.

addresses: CWE-863

Supervision identifies cases where authorization logic incorrectly permits unauthorized actions.

addresses: CWE-863

Defining permitted attribute values and auditing modifications reduces the chance of incorrect authorization outcomes due to tampered or missing labels.

addresses: CWE-863

The authorization process and usage restrictions help prevent incorrect authorization for remote access types.

addresses: CWE-863

Establishing configuration and connection requirements helps ensure correct rather than incorrect authorization for wireless access.

addresses: CWE-863

Establishing connection authorization processes for mobile devices helps ensure authorization decisions are correctly implemented rather than incorrect.

addresses: CWE-863

Monitoring account use, notifying on changes, and reviewing accounts for compliance corrects incorrect authorization assignments.

addresses: CWE-863

Ensures authorization decisions for external system use are correctly implemented and enforced.

References