Cyber Resilience

CVE-2023-27407

RCE in Siemens Scalance Lpe9403 Firmware ≤ 2.1

Published
09 May 2023
Modified
21 November 2024
Patch / advisory
CVSS Score v3.1 9.9
Click a component to see what it means
Raw vectorCVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H
EPSS Score 0.013 68th percentile
Risk Priority 71 floored blend · peak EPSS

Summary

CVE-2023-27407 is a critical-severity Command Injection (CWE-77) vulnerability in Siemens Scalance Lpe9403 Firmware. Its CVSS base score is 9.9 (Critical).

Operationally, exploitation aligns with the MITRE ATT&CK technique Command and Scripting Interpreter (T1059); ranked in the top 32% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.

OWASP Top 10 for Web (2025)

EU & UK References

Vulnerability Data

A vulnerability has been identified in SCALANCE LPE9403 (All versions < V2.1). The web based management of affected device does not properly validate user input, making it susceptible to command injection. This could allow an authenticated remote attacker to access…

more

the underlying operating system as the root user.

CWE(s)

Related Threats

MITRE ATT&CK Enterprise Techniques

T1059 Command and Scripting Interpreter Execution
Adversaries may abuse command and script interpreters to execute commands, scripts, or binaries.
T1059.003 Windows Command Shell Execution
Adversaries may abuse the Windows command shell for execution.
T1059.004 Unix Shell Execution
Adversaries may abuse Unix shell commands and scripts for execution.
T1190 Exploit Public-Facing Application Initial Access
Adversaries may attempt to exploit a weakness in an Internet-facing host or system to initially access a network.
T1059.001 PowerShell Execution
Adversaries may abuse PowerShell commands and scripts for execution.
T1059.008 Network Device CLI Execution
Adversaries may abuse scripting or built-in command line interpreters (CLI) on network devices to execute malicious command and payloads.
Derived from this CVE’s CWE(s) via the direct CWE→ATT&CK cross-walk.

CVEs Like This One

CVE-2025-27393Same product: Siemens Scalance Lpe9403
CVE-2025-27392Same product: Siemens Scalance Lpe9403
CVE-2025-27394Same product: Siemens Scalance Lpe9403
CVE-2025-27398Same product: Siemens Scalance Lpe9403
CVE-2024-39568Same vendor: Siemens
CVE-2024-39570Same vendor: Siemens
CVE-2023-36753Same vendor: Siemens
CVE-2024-56837Same vendor: Siemens
CVE-2024-39569Same vendor: Siemens
CVE-2024-56836Same vendor: Siemens

Affected Assets

siemens
scalance lpe9403 firmware
≤ 2.1

Mitigating Controls

Control response

Prevent
Stop it (NIST 800-53)

Detect
Catch it (NIST detect / respond)

Harden
Shrink the surface (DISA STIG)

Validate
Prove the fix (OWASP ASVS)
  • V1.2.3
  • V1.2.5
  • V1.2.8
  • V1.2.9

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-78

Platform-independent apps typically execute inside a managed runtime or sandbox that restricts direct OS command execution, reducing the ability to exploit OS command injection.

addresses: CWE-78

Validates inputs to block special elements that would alter OS command execution.

Mitigating Controls (NIST CSF 2.0) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.

PR.PS-06 mostly match
prevents

Secure SDLC practices directly require input validation and neutralization that prevent command injection.

DE.CM-09 partial match
prevents

Runtime monitoring of software and data can detect anomalous command execution resulting from injection.

ID.RA-01 partial match
prevents

Identifying recorded vulnerabilities enables remediation of command-injection flaws before exploitation.

PR.PS-02 partial match
prevents

Routine patching/maintenance can remediate known command-injection CVEs in dependencies (partial forward) but does nothing to stop developers from introducing improper neutralization in custom code (none reverse).

Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.

prevents

Secure coding standards require proper escaping and parameterization of commands, directly eliminating CWE-77.

finds

Security testing in development catches command-injection vulnerabilities before release.

prevents

Secure development life cycle mandates input validation and command construction practices that directly prevent command injection.

prevents

Application security requirements explicitly call for controls against injection flaws including command injection.

prevents

Secure architecture principles reduce the attack surface but do not prescribe the specific neutralization techniques needed.

none

Environment separation limits the blast radius of an exploited command injection but does not prevent the flaw itself.

References