Security Resilience

CVE-2023-43035

Ibm Sterling Control Center 6.2.1 … 6.4.0

Published
10 April 2025
Modified
18 July 2025
Patch / advisory
CVSS Score v3.1 4.0
Click a component to see what it means
Raw vectorCVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N
EPSS Score 0.0016 5th percentile
Risk Priority 32 floored blend · peak EPSS

CVSS and EPSS are reproduced from their sources (NVD, FIRST EPSS). Risk Priority is our own derived reading, not an NVD score.

Summary

CVE-2023-43035 is a medium-severity Use of Web Browser Cache Containing Sensitive Information (CWE-525) vulnerability in Ibm Sterling Control Center. Its CVSS base score is 4.0 (Medium).

Operationally, exploitation aligns with the MITRE ATT&CK technique Data Obfuscation (T1001); ranked at the 5th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

OWASP Top 10 for Web (2025)

EU & UK References

Vulnerability Data

IBM Sterling Control Center 6.2.1, 6.3.1, and 6.4.0 allows web pages to be stored locally which can be read by another user on the system.

CWE(s)

Related Threats

MITRE ATT&CK Enterprise Techniques

T1001 Data Obfuscation Command And Control
Adversaries may obfuscate command and control traffic to make it more difficult to detect.
T1001.001 Junk Data Command And Control
Adversaries may add junk data to protocols used for command and control to make detection more difficult.
T1005 Data from Local System Collection
Adversaries may search local system sources, such as file systems, configuration files, local databases, virtual machine files, or process memory, to find files of interest and sensitive data prior to Exfiltration.
T1006 Direct Volume Access Stealth
Adversaries may directly access a volume to bypass file access controls and file system monitoring.
T1011.001 Exfiltration Over Bluetooth Exfiltration
Adversaries may attempt to exfiltrate data over Bluetooth rather than the command and control channel.
T1014 Rootkit Stealth
Adversaries may use rootkits to hide the presence of programs, files, network connections, services, drivers, and other system components.
Derived from this CVE’s CWE(s) via the direct CWE→ATT&CK cross-walk.

CVEs Like This One

CVE-2025-1348Same product: Ibm Aix
CVE-2023-42007Same product: Ibm Aix
CVE-2023-35020Same product: Ibm Aix
CVE-2025-33133Same product: Ibm Aix
CVE-2025-33132Same product: Ibm Aix
CVE-2025-33126Same product: Ibm Aix
CVE-2025-33131Same product: Ibm Aix
CVE-2023-47152Same product: Ibm Aix
CVE-2026-6051Same product: Ibm Aix
CVE-2024-41783Same product: Ibm Aix

Affected Assets

ibm
sterling control center
6.2.1, 6.3.1, 6.4.0

Mitigating Controls

Control response

Prevent
Stop it (NIST 800-53)

—

Detect
Catch it (NIST detect / respond)

—

Harden
Shrink the surface (DISA STIG)

—

Validate
Prove the fix (OWASP ASVS)
  • V14.2.5
  • V14.3.2

Mitigating Controls (NIST CSF 2.0) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.

PR.PS-01 partial match
blocks

Configuration baselines and enforcement directly require proper Cache-Control and related headers.

PR.PS-06 partial match
blocks

Secure SDLC practices include defining and verifying appropriate web caching policies for sensitive content.

Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.

degrades

Endpoint device configuration can enforce cache-clearing or no-cache policies for sensitive web content.

blocks

A.8.26 only requires that security requirements (including those that could address caching) be identified and specified during development or acquisition; it does not itself enforce any caching policy or stop the weakness from being exploitable.

prevents

Secure coding standards can mandate proper cache-control headers and form-field handling to prevent sensitive data retention.

References