CVE-2023-43632 is a critical-severity Memory Allocation with Excessive Size Value (CWE-789) vulnerability in Linuxfoundation Edge Virtualization Engine. Its CVSS base score is 9.0 (Critical).
Operationally, ranked at the 22.0th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2023-48032
Vulnerability details
As noted in the “VTPM.md” file in the eve documentation, “VTPM is a server listening on port 8877 in EVE, exposing limited functionality of the TPM to the clients. VTPM allows clients to execute tpm2-tools binaries from a list of…
more
hardcoded options” The communication with this server is done using protobuf, and the data is comprised of 2 parts: 1. Header 2. Data When a connection is made, the server is waiting for 4 bytes of data, which will be the header, and these 4 bytes would be parsed as uint32 size of the actual data to come. Then, in the function “handleRequest” this size is then used in order to allocate a payload on the stack for the incoming data. As this payload is allocated on the stack, this will allow overflowing the stack size allocated for the relevant process with freely controlled data. * An attacker can crash the system. * An attacker can gain control over the system, specifically on the “vtpm_server” process which has very high privileges.
- CWE(s)
Related Threats
No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.
Affected Assets
Mitigating Controls
Likely Mitigating Controls AI
Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.
This control implements explicit throttling on session allocation, addressing the weakness of allocating resources without limits.
Plan testing exercises resource allocation limits and throttling during simulated failures, directly addressing weaknesses that allow unbounded resource use.
Contingency plan updates ensure recovery strategies address unbounded resource allocation, making it harder for attackers to exploit lack of throttling to cause prolonged outages.
Provides continuity when unbounded resource allocation at the primary site leads to exhaustion and downtime.
Alternate services allow operations to continue when primary allocation of resources lacks limits or throttling.
Explicit planning of security-related actions requires defining limits, windows, and resource allocations, making allocation without throttling far less likely.
Measures of performance include tracking allocation behavior and throttling effectiveness, reducing the window for resource exhaustion attacks.
Imposes an inactivity-based limit on network resource allocation, throttling the number of concurrently held connections.