Cyber Resilience

CVE-2024-27337

High

Published: 03 April 2024

Published
03 April 2024
Modified
03 June 2025
KEV Added
Patch
CVSS Score v3.1 7.8 CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
EPSS Score 0.0103 77.8th percentile
Risk Priority 16 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2024-27337 is a high-severity Stack-based Buffer Overflow (CWE-121) vulnerability in Tungstenautomation Power Pdf. Its CVSS base score is 7.8 (High).

Operationally, ranked in the top 22.2% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.

EU & UK References

Vulnerability details

Kofax Power PDF TIF File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Kofax Power PDF. User interaction is required to exploit this vulnerability in that the…

more

target must visit a malicious page or open a malicious file. The specific flaw exists within the parsing of TIF files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. Was ZDI-CAN-22033.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

tungstenautomation
power pdf
≤ 5.0.0.17

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-787

Out-of-bounds writes that corrupt control flow or inject shellcode are rendered non-executable by the same memory protections.