Raw vector
CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:HCVSS and EPSS are reproduced from their sources (NVD, FIRST EPSS). Risk Priority is our own derived reading, not an NVD score.
Summary
CVE-2024-37569 is a high-severity Command Injection (CWE-77) vulnerability in Mitel 6869I Sip Firmware. Its CVSS base score is 8.8 (High).
Operationally, exploitation aligns with the MITRE ATT&CK technique Command and Scripting Interpreter (T1059); ranked in the top 13% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog; a public proof-of-concept is referenced.
The strongest mitigations our analysis identified map to SA-11 (Developer Testing and Evaluation) and SI-10 (Information Input Validation) — see the control section below for these in your framework.
OWASP Top 10 for Web (2025)
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2024-36765
Vulnerability Data
An issue was discovered on Mitel 6869i through 4.5.0.41 and 5.x through 5.0.0.1018 devices. A command injection vulnerability exists in the hostname parameter taken in by the provis.html endpoint. The provis.html endpoint performs no sanitization on the hostname parameter (sent…
more
by an authenticated user), which is subsequently written to disk. During boot, the hostname parameter is executed as part of a series of shell commands. Attackers can achieve remote code execution in the root context by placing shell metacharacters in the hostname parameter.
- CWE(s)
Related Threats
MITRE ATT&CK Enterprise Techniques
CVEs Like This One
Affected Assets
Mitigating Controls
Control response
—
—
—
V1.2.3V1.2.5V1.2.8V1.2.9
Mitigating Controls (NIST 800-53 r5) AI
Developer testing and evaluation can discover command-construction flaws before deployment.
Input validation directly stops construction of commands from untrusted data containing special elements.
Secure engineering principles include proper neutralization and safe command construction practices.
Mitigating Controls (NIST CSF 2.0) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.
Secure SDLC practices directly require input validation and neutralization that prevent command injection.
Runtime monitoring of software and data can detect anomalous command execution resulting from injection.
Identifying recorded vulnerabilities enables remediation of command-injection flaws before exploitation.
Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.
Secure coding standards require proper escaping and parameterization of commands, directly eliminating CWE-77.
Security testing in development catches command-injection vulnerabilities before release.
Secure development life cycle mandates input validation and command construction practices that directly prevent command injection.
Application security requirements explicitly call for controls against injection flaws including command injection.
Secure architecture principles reduce the attack surface but do not prescribe the specific neutralization techniques needed.