Cyber Resilience

CVE-2024-4241

High

Published: 26 April 2024

Published
26 April 2024
Modified
27 January 2025
KEV Added
Patch
CVSS Score v3.1 8.8 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS Score 0.0036 58.4th percentile
Risk Priority 18 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2024-4241 is a high-severity Stack-based Buffer Overflow (CWE-121) vulnerability in Tenda W9 Firmware. Its CVSS base score is 8.8 (High).

Operationally, exploitation aligns with the MITRE ATT&CK technique Exploit Public-Facing Application (T1190); ranked in the top 41.6% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.

EU & UK References

Vulnerability details

A vulnerability was found in Tenda W9 1.0.0.7(4456). It has been declared as critical. This vulnerability affects the function formQosManageDouble_auto. The manipulation of the argument ssidIndex leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of…

more

this vulnerability is VDB-262132. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.

CWE(s)

Related Threats

MITRE ATT&CK Enterprise TechniquesAI

T1190 Exploit Public-Facing Application Initial Access
Adversaries may attempt to exploit a weakness in an Internet-facing host or system to initially access a network.
Why these techniques?

Stack-based buffer overflow in the remotely accessible formQosManageDouble_auto function of the Tenda W9 router's web interface enables exploitation of a public-facing application for potential remote code execution or denial of service.

Affected Assets

tenda
w9 firmware
1.0.0.7\(4456\)

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-787

Out-of-bounds writes that corrupt control flow or inject shellcode are rendered non-executable by the same memory protections.

References