Cyber Resilience

CVE-2024-51445

High

Published: 13 May 2025

Published
13 May 2025
Modified
23 September 2025
KEV Added
Patch
CVSS Score v4 7.1 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS Score 0.0018 40.0th percentile
Risk Priority 14 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2024-51445 is a high-severity Improper Restriction of XML External Entity Reference (CWE-611) vulnerability in Siemens Polarion Alm. Its CVSS base score is 7.1 (High).

Operationally, ranked at the 40.0th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

EU & UK References

Vulnerability details

A vulnerability has been identified in Polarion V2310 (All versions), Polarion V2404 (All versions < V2404.4). The affected application contains a XML External Entity Injection (XXE) vulnerability in the docx import feature. This could allow an authenticated remote attacker to…

more

read arbitrary data from the application server.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

siemens
polarion alm
2310.0 · 2404.0 — 2404.4

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-611

Penetration testing includes XML external entity payloads, detecting XXE vulnerabilities and enabling their mitigation.