Summary

CVE-2025-32826 is a high-severity SQL Injection (CWE-89) vulnerability in Siemens Telecontrol Server Basic. Its CVSS base score is 8.7 (High).

Operationally, ranked at the 12.5th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

Deeper analysis

TeleControl Server Basic versions prior to V3.1.2.2 are affected by a SQL injection vulnerability in the internally used GetActiveProjects method, tracked as CVE-2025-32826 with a CVSS score of 8.7 and classified under CWE-89. The flaw allows manipulation of database queries through this method on systems exposing port 8000.

An authenticated remote attacker who can reach the affected service can exploit the injection to bypass authorization, read from and write to the application database, and execute code with NT AUTHORITY\NetworkService privileges.

The Siemens product certificate SSA-443402 at cert-portal.siemens.com details the affected versions and recommended remediation steps.

The EPSS score for this CVE rose materially from a low starting value of 0.0004 to a peak of 0.0100, indicating that exploitation interest emerged after disclosure.

EU & UK References

Vulnerability details

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'GetActiveProjects' method. This could allow an authenticated remote attacker to bypass authorization controls, to read…

more

from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

siemens
telecontrol server basic
≤ 3.1.2.2

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-89

Penetration testing uses SQL injection payloads against database interfaces, identifying and supporting fixes for SQL injection weaknesses.

addresses: CWE-89

Validates query inputs to prevent SQL syntax or command manipulation.