CVE-2025-68476
Published: 22 December 2025
Summary
CVE-2025-68476 is a high-severity Path Traversal (CWE-22) vulnerability. Its CVSS base score is 8.2 (High).
Operationally, ranked at the 34.5th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2025-204753
Vulnerability details
KEDA is a Kubernetes-based Event Driven Autoscaling component. Prior to versions 2.17.3 and 2.18.3, an Arbitrary File Read vulnerability has been identified in KEDA, potentially affecting any KEDA resource that uses TriggerAuthentication to configure HashiCorp Vault authentication. The vulnerability stems…
more
from an incorrect or insufficient path validation when loading the Service Account Token specified in spec.hashiCorpVault.credential.serviceAccount. An attacker with permissions to create or modify a TriggerAuthentication resource can exfiltrate the content of any file from the node's filesystem (where the KEDA pod resides) by directing the file's content to a server under their control, as part of the Vault authentication request. The potential impact includes the exfiltration of sensitive system information, such as secrets, keys, or the content of files like /etc/passwd. This issue has been patched in versions 2.17.3 and 2.18.3.
- CWE(s)
Related Threats
CVEs Like This One
Affected Assets
Mitigating Controls
Likely Mitigating Controls AI
Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.
Periodic review and update of procedures reduces incorrect authorization implementations over time.
Supervision identifies cases where authorization logic incorrectly permits unauthorized actions.
Defining permitted attribute values and auditing modifications reduces the chance of incorrect authorization outcomes due to tampered or missing labels.
The authorization process and usage restrictions help prevent incorrect authorization for remote access types.
Establishing configuration and connection requirements helps ensure correct rather than incorrect authorization for wireless access.
Establishing connection authorization processes for mobile devices helps ensure authorization decisions are correctly implemented rather than incorrect.
Monitoring account use, notifying on changes, and reviewing accounts for compliance corrects incorrect authorization assignments.
Ensures authorization decisions for external system use are correctly implemented and enforced.