Cyber Resilience

CVE-2024-30247

RCE in Nextcloudpi ≤ 1.53.1

Published
29 March 2024
Modified
17 June 2026
Patch / advisory
CVSS Score v3.1 10.0
Click a component to see what it means
Raw vectorCVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H
EPSS Score 0.021 81th percentile
Risk Priority 78 floored blend · peak EPSS

CVSS and EPSS are reproduced from their sources (NVD, FIRST EPSS). Risk Priority is our own derived reading, not an NVD score.

Summary

CVE-2024-30247 is a critical-severity OS Command Injection (CWE-78) vulnerability in Nextcloud Nextcloudpi. Its CVSS base score is 10.0 (Critical).

Operationally, exploitation aligns with the MITRE ATT&CK technique Command and Scripting Interpreter (T1059); ranked in the top 19% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.

The strongest mitigations our analysis identified map to SA-11 (Developer Testing and Evaluation) and SI-10 (Information Input Validation) — see the control section below for these in your framework.

OWASP Top 10 for Web (2025)

EU & UK References

Vulnerability Data

NextcloudPi is a ready to use image for Virtual Machines, Raspberry Pi, Odroid HC1, Rock64 and other boards. A command injection vulnerability in NextCloudPi allows command execution as the root user via the NextCloudPi web-panel. Due to a security misconfiguration…

more

this can be used by anyone with access to NextCloudPi web-panel, no authentication is required. It is recommended that the NextCloudPi is upgraded to 1.53.1.

CWE(s)

Related Threats

MITRE ATT&CK Enterprise Techniques

T1059 Command and Scripting Interpreter Execution
Adversaries may abuse command and script interpreters to execute commands, scripts, or binaries.
T1059.003 Windows Command Shell Execution
Adversaries may abuse the Windows command shell for execution.
T1059.004 Unix Shell Execution
Adversaries may abuse Unix shell commands and scripts for execution.
T1059.001 PowerShell Execution
Adversaries may abuse PowerShell commands and scripts for execution.
T1190 Exploit Public-Facing Application Initial Access
Adversaries may attempt to exploit a weakness in an Internet-facing host or system to initially access a network.
Derived from this CVE’s CWE(s) via the direct CWE→ATT&CK cross-walk.

CVEs Like This One

CVE-2023-31128Same vendor: Nextcloud
CVE-2023-26482Same vendor: Nextcloud
CVE-2025-8628Shared CWE-78
CVE-2024-22836Shared CWE-78
CVE-2023-25826Shared CWE-78
CVE-2026-65590Shared CWE-78
CVE-2026-72880Shared CWE-78
CVE-2024-28125Shared CWE-78
CVE-2026-9207Shared CWE-78
CVE-2026-33145Shared CWE-78

Affected Assets

nextcloud
nextcloudpi
≤ 1.53.1

Mitigating Controls

Control response

Prevent
Stop it (NIST 800-53)

Detect
Catch it (NIST detect / respond)

Harden
Shrink the surface (DISA STIG)

Validate
Prove the fix (OWASP ASVS)
  • V1.2.5
  • V1.2.8
  • V15.2.5

Mitigating Controls (NIST 800-53 r5) AI

Developer testing and evaluation can discover missing or incorrect command sanitization during development.

Input validation directly neutralizes or rejects special characters that would otherwise alter OS command structure.

Least privilege reduces the permissions available to any process that could be subverted by injected commands.

Least functionality restricts available OS commands and interpreters, limiting the blast radius of injection.

Secure engineering principles require proper neutralization of untrusted input before command construction.

Mitigating Controls (NIST CSF 2.0) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.

PR.PS-06 mostly match
prevents

PR.PS-06's SDLC practices directly require secure coding and input handling that blocks command-injection defects, yet the single broad outcome leaves many specific neutralization vectors and verification gaps unaddressed.

PR.PS-02 partial match
prevents

Routine patching/maintenance can remediate known command-injection CVEs in dependencies (partial forward) but does nothing to stop developers from introducing improper neutralization in custom code (none reverse).

Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.

finds

Security testing and code review target insecure use of operating-system command interfaces, catching command-injection flaws introduced during development.

References