Raw vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XSummary
CVE-2024-44102 is a critical-severity Deserialization of Untrusted Data (CWE-502) vulnerability in Siemens Telecontrol Server Basic. Its CVSS base score is 10.0 (Critical).
Operationally, exploitation aligns with the MITRE ATT&CK technique Exploit Public-Facing Application (T1190); ranked in the top 40% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.
The strongest mitigations our analysis identified map to SA-11 (Developer Testing and Evaluation) and SI-10 (Information Input Validation) — see the control section below for these in your framework.
Deeper analysis AI-assisted summary
Synthesised by an AI model from the NVD description and linked references — a reading aid, not an authoritative source.
A critical deserialization vulnerability, tracked as CVE-2024-44102 and assigned CWE-502, affects multiple versions of Siemens TeleControl Server Basic and PP TeleControl Server Basic (including 8, 32, 64, 256, 1000, and 5000 variants up to V3.1) when redundancy is configured. All listed builds prior to V3.1.2.1 accept user-supplied serialized objects without adequate validation, enabling remote code execution.
An unauthenticated attacker with network access can send a maliciously crafted serialized object to the affected server. Successful exploitation grants arbitrary code execution with SYSTEM privileges on the device, resulting in full control over the telecontrol system.
The Siemens advisory SSA-454789 recommends upgrading to V3.1.2.1 or later for all affected TeleControl Server Basic products to eliminate the insecure deserialization path.
EPSS scores have remained low and stable near 0.09 with no material post-disclosure increase, indicating limited observed exploitation interest to date.
OWASP Top 10 for Web (2025)
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2024-40866
Vulnerability Data
A vulnerability has been identified in PP TeleControl Server Basic 1000 to 5000 V3.1 (6NH9910-0AA31-0AE1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 256 to 1000 V3.1 (6NH9910-0AA31-0AD1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl…
more
Server Basic 32 to 64 V3.1 (6NH9910-0AA31-0AF1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 64 to 256 V3.1 (6NH9910-0AA31-0AC1) (All versions < V3.1.2.1 with redundancy configured), PP TeleControl Server Basic 8 to 32 V3.1 (6NH9910-0AA31-0AB1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 1000 V3.1 (6NH9910-0AA31-0AD0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 256 V3.1 (6NH9910-0AA31-0AC0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 32 V3.1 (6NH9910-0AA31-0AF0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 5000 V3.1 (6NH9910-0AA31-0AE0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 64 V3.1 (6NH9910-0AA31-0AB0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic 8 V3.1 (6NH9910-0AA31-0AA0) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Serv Upgr (6NH9910-0AA31-0GA1) (All versions < V3.1.2.1 with redundancy configured), TeleControl Server Basic Upgr V3.1 (6NH9910-0AA31-0GA0) (All versions < V3.1.2.1 with redundancy configured). The affected system allows remote users to send maliciously crafted objects. Due to insecure deserialization of user-supplied content by the affected software, an unauthenticated attacker could exploit this vulnerability by sending a maliciously crafted serialized object. This could allow the attacker to execute arbitrary code on the device with SYSTEM privileges.
- CWE(s)
Related Threats
MITRE ATT&CK Enterprise Techniques
CVEs Like This One
Affected Assets
Mitigating Controls
Mitigating Controls (NIST 800-53 r5) AI
Developer testing and evaluation can uncover deserialization flaws before deployment.
Input validation directly stops deserialization of untrusted data by ensuring inputs are valid before processing.
Engineering principles such as safe deserialization and input sanitization structurally prevent the weakness from being introduced.
Integrity verification tools can detect malformed or tampered serialized data after the fact.
Mitigating Controls (NIST CSF 2.0) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.
PR.PS-02 addresses only post-deployment updates/patching and cannot prevent introduction of unsafe deserialization code, yet it can remediate some instances when the flaw exists in outdated libraries or components.
Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.
Security testing includes validation of deserialization routines and the use of untrusted data, reducing the likelihood that unsafe object reconstruction will be deployed.
Requiring vetted libraries, regular updates and SAST before release reduces the likelihood that deserialization logic will accept and act on attacker-controlled serialized objects.
Regular scanning of third-party libraries and timely patching reduce the likelihood that unsafe deserialization vulnerabilities remain active.
Mandatory malware scanning of data received over networks or storage media intercepts malicious serialized payloads before they are deserialized by the target application.