Cyber Resilience

CVE-2025-10708

MediumPublic PoC

Published: 19 September 2025

Published
19 September 2025
Modified
03 October 2025
KEV Added
Patch
CVSS Score v4 5.5 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS Score 0.0057 69.1th percentile
Risk Priority 11 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2025-10708 is a medium-severity Path Traversal (CWE-22) vulnerability in Four-Faith Water Conservancy Informatization. Its CVSS base score is 5.5 (Medium).

Operationally, exploitation aligns with the MITRE ATT&CK technique Data from Local System (T1005); ranked in the top 30.9% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog; a public proof-of-concept is referenced.

EU & UK References

Vulnerability details

A security vulnerability has been detected in Four-Faith Water Conservancy Informatization Platform 1.0. Affected by this vulnerability is an unknown functionality of the file /history/historyDownload.do;usrlogout.do. The manipulation of the argument fileName leads to path traversal. Remote exploitation of the attack…

more

is possible. The exploit has been disclosed publicly and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

CWE(s)

Related Threats

MITRE ATT&CK Enterprise TechniquesAI

T1005 Data from Local System Collection
Adversaries may search local system sources, such as file systems, configuration files, local databases, virtual machine files, or process memory, to find files of interest and sensitive data prior to Exfiltration.
T1006 Direct Volume Access Stealth
Adversaries may directly access a volume to bypass file access controls and file system monitoring.
T1190 Exploit Public-Facing Application Initial Access
Adversaries may attempt to exploit a weakness in an Internet-facing host or system to initially access a network.
Why these techniques?

Path traversal vulnerability enables exploitation of public-facing web application (T1190) for arbitrary remote file reads, facilitating data from local system (T1005) and direct volume access (T1006) as noted in advisories.

Affected Assets

four-faith
water conservancy informatization
1.0

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-22

Validates pathnames and filenames to prevent traversal outside intended directories.

References