Cyber Resilience

CVE-2025-15114

CriticalPublic PoC

Published: 30 December 2025

Published
30 December 2025
Modified
11 March 2026
KEV Added
Patch
CVSS Score v4 9.3 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS Score 0.0050 39.2th percentile
Risk Priority 70 floored blend · peak EPSS

Summary

CVE-2025-15114 is a critical-severity File Descriptor Leak (CWE-403) vulnerability in Kseniasecurity Lares Firmware. Its CVSS base score is 9.3 (Critical).

Operationally, ranked at the 39.2th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog; a public proof-of-concept is referenced.

OWASP Top 10 for Web (2025)

EU & UK References

Vulnerability details

Ksenia Security lares (legacy model) Home Automation version 1.6 contains a critical security flaw that exposes the alarm system PIN in the 'basisInfo' XML file after authentication. Attackers can retrieve the PIN from the server response to bypass security measures…

more

and disable the alarm system without additional authentication.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

kseniasecurity
lares firmware
1.6

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-668

Controls whether organization resources are exposed to external system spheres by permitting or prohibiting their use.

addresses: CWE-668

The control ensures information is not released into a security sphere where the recipient lacks matching access authorizations.

addresses: CWE-668

The control ensures information resources are not exposed to the incorrect (public) sphere through review and authorization.

addresses: CWE-668

Protects against data mining that would expose resources to unauthorized spheres by enforcing detection and controls.

addresses: CWE-668

Restricts information flows to ensure resources are not exposed to incorrect or unauthorized spheres.

addresses: CWE-668

Controlling internal connections prevents exposure of resources to unintended internal spheres.

addresses: CWE-668

Knowing exact processing and storage locations helps avoid exposure of resources to incorrect spheres.

addresses: CWE-668

The control prevents exposure of the media resource to the wrong security sphere.

References