Raw vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XCVSS and EPSS are reproduced from their sources (NVD, FIRST EPSS). EPSS, Forum of Incident Response and Security Teams (FIRST), epss.first.org. Risk Priority is our own derived reading, not an NVD score.
Summary
CVE-2026-11826 is a high-severity Heap-based Buffer Overflow (CWE-122) vulnerability. Its CVSS base score is 8.7 (High).
Operationally, exploitation aligns with the MITRE ATT&CK technique Exploitation for Privilege Escalation (T1068); ranked in the top 45% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog; a public proof-of-concept is referenced.
The strongest mitigations our analysis identified map to SA-11 (Developer Testing and Evaluation) and SI-10 (Information Input Validation) — see the control section below for these in your framework.
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2026-45380
Vulnerability Data
OpenPLC_v3 contains a heap-based buffer overflow in the getData() function in webserver/core/modbus_master.cpp. getData() reads characters between two delimiters into a caller-supplied buffer with no size parameter and no bounds check. In parseConfig() the function is invoked with the 100-byte heap-allocated…
more
MB_device.dev_name field. An authenticated attacker with access to the OpenPLC web interface can send a crafted HTTP POST to the /modbus endpoint with an oversized device_name value; the value is persisted to mbconfig.cfg and parsed on load, overflowing dev_name and overwriting adjacent struct fields (protocol at offset 108, dev_address at offset 109, ip_port at offset 210). A 200-byte payload writes 100 bytes past the allocation. The result is heap corruption leading to runtime crash and denial of service of the PLC process control loop, with attacker-controlled overwrite of adjacent configuration fields. The upstream repository was archived on 2026-04-04 and no fix is expected; the vendor has confirmed the issue does not affect OpenPLC Runtime v4.
- CWE(s)
Related Threats
MITRE ATT&CK Enterprise Techniques
MITRE ATT&CK v20.0
CVEs Like This One
Affected Assets
Mitigating Controls
Control response
—
—
—
V1.4.1
Mitigating Controls (NIST 800-53 r5)
Our mappings, made for this CVE.
Developer testing and evaluation (including fuzzing and memory-error detectors) can discover heap overflows after they have been coded.
Input validation enforces bounds checking on data written to heap buffers, directly stopping the overflow condition from being introduced.
Security engineering principles require use of memory-safe constructs and bounds-checked allocation routines that avoid introducing heap overflows.
Memory-protection mechanisms limit the ability of a heap overflow to execute attacker-controlled code or corrupt adjacent structures.
Mitigating Controls (NIST CSF 2.0)
Our mappings, derived directly from the weakness types (CWEs) cited in the NVD entry via our CWE→CSF cross-walk — links open the control.
Secure-development practices directly require bounds checking and safe memory handling that prevent heap overflows.
Vulnerability scanning and recording can discover heap-overflow flaws but does not prevent their introduction in code.
Timely patching removes known heap-overflow instances after they exist.
Mitigating Controls (ISO/IEC 27001:2022 Annex A)
Our mappings, derived directly from the weakness types (CWEs) cited in the NVD entry via our CWE→ISO cross-walk — links open the control.
Security testing in development and acceptance can detect heap overflows before release.
Secure coding standards directly prescribe techniques (safe functions, bounds checks) that prevent heap-based buffer overflows.
A.8.8's reach is DISCLOSURE — it surfaces heap-based buffer overflows only where they appear as published CVEs in third-party components in the inventory. CWE-122 is overwhelmingly an implementation-phase defect in custom code, which A.8.8 does not read; the disclosed third-party share is a minority, matching the same logic that graded A.8.8 -> CWE-89 at `partial`.