Raw vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XCVSS and EPSS are reproduced from their sources (NVD, FIRST EPSS). Risk Priority is our own derived reading, not an NVD score.
Summary
CVE-2026-19348 is a high-severity Injection (CWE-74) vulnerability. Its CVSS base score is 8.9 (High).
Operationally, exploitation aligns with the MITRE ATT&CK technique Dynamic Linker Hijacking (T1574.006); ranked in the top 21% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.
The strongest mitigations our analysis identified map to SA-11 (Developer Testing and Evaluation) and SI-10 (Information Input Validation) — see the control section below for these in your framework.
OWASP Top 10 for Web (2025)
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2026-54917
Vulnerability Data
A security flaw has been discovered in Shenzhen Aitemi M300 Wi-Fi Repeater r0-ea7890a. Impacted is the function sprintf of the file /protocol.csp?fname=net&opt=smacfilter_conf&function=set&act=add&name=test&enable=1. Performing a manipulation of the argument enable/name/mac results in command injection. The attack may be initiated remotely. The…
more
exploit has been released to the public and may be used for attacks.
- CWE(s)
Related Threats
MITRE ATT&CK Enterprise Techniques
CVEs Like This One
Affected Assets
Mitigating Controls
Control response
—
—
—
V1.2.1V1.2.3V1.2.5V1.2.8
Mitigating Controls (NIST 800-53 r5) AI
Developer testing and evaluation can discover command-construction flaws before deployment.
SI-10 directly requires validation of information inputs to reject malformed or special-element content before it reaches downstream parsers.
Secure engineering principles include proper neutralization and safe command construction practices.
Mitigating Controls (NIST CSF 2.0) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.
Runtime monitoring of software and data can detect anomalous command execution resulting from injection.
Identifying recorded vulnerabilities enables remediation of command-injection flaws before exploitation.
Secure SDLC practices directly require input validation and output encoding that prevent injection flaws.
Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.
Logging supports detection of injection attempts but does not prevent the weakness.
Monitoring activities can identify active injection attacks after they occur.
Secure development life cycle mandates input validation and output encoding that directly prevent injection flaws.
Application security requirements explicitly call for controls against injection attacks in software design.
Secure architecture principles reduce injection surfaces but do not prescribe specific neutralization techniques.
Secure coding standards require proper neutralization of special elements, directly addressing CWE-74.