CVE-2026-26093
RCE in Owlcyberdefense Opds-Talon 2.2.0.4
Raw vector
CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:XSummary
CVE-2026-26093 is a high-severity Command Injection (CWE-77) vulnerability in Owlcyberdefense Opds-Talon. Its CVSS base score is 8.7 (High).
Operationally, exploitation aligns with the MITRE ATT&CK technique Command and Scripting Interpreter (T1059); ranked in the top 37% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.
The strongest mitigations our analysis identified map to SA-11 (Developer Testing and Evaluation) and SI-10 (Information Input Validation) — see the control section below for these in your framework.
Deeper analysis AI-assisted summary
Synthesised by an AI model from the NVD description and linked references — a reading aid, not an authoritative source.
CVE-2026-26093 is a command injection vulnerability (CWE-77) affecting Owl OPDS version 2.2.0.4, caused by improper neutralization of special elements used in a command. Published on 2026-02-20, the flaw enables command injection through a crafted network request.
The vulnerability carries a CVSS v3.1 base score of 9.8 (AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H), indicating it is exploitable remotely over the network with low attack complexity, no privileges, authentication, or user interaction required, and unchanged impact scope. Any unauthenticated attacker can send a malicious request to inject and execute arbitrary commands, resulting in high confidentiality, integrity, and availability impacts, such as full system compromise.
Mitigation details are available in the Nozomi Networks vulnerability advisory at https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2026-26093.
OWASP Top 10 for Web (2025)
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2026-7755
Vulnerability Data
Improper Neutralization of Special Elements used in a Command ('Command Injection') in Owl opds 2.2.0.4 allows Command Injection via a crafted network request.
- CWE(s)
Related Threats
MITRE ATT&CK Enterprise Techniques
CVEs Like This One
Affected Assets
Mitigating Controls
Control response
—
—
—
V1.2.3V1.2.5V1.2.8V1.2.9
Mitigating Controls (NIST 800-53 r5) AI
Developer testing and evaluation can discover command-construction flaws before deployment.
Input validation directly stops construction of commands from untrusted data containing special elements.
Secure engineering principles include proper neutralization and safe command construction practices.
Mitigating Controls (NIST CSF 2.0) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.
Secure SDLC practices directly require input validation and neutralization that prevent command injection.
Runtime monitoring of software and data can detect anomalous command execution resulting from injection.
Identifying recorded vulnerabilities enables remediation of command-injection flaws before exploitation.
Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI
Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.
Secure coding standards require proper escaping and parameterization of commands, directly eliminating CWE-77.
Security testing in development catches command-injection vulnerabilities before release.
Secure development life cycle mandates input validation and command construction practices that directly prevent command injection.
Application security requirements explicitly call for controls against injection flaws including command injection.
Secure architecture principles reduce the attack surface but do not prescribe the specific neutralization techniques needed.
Environment separation limits the blast radius of an exploited command injection but does not prevent the flaw itself.