CVE-2021-27385
Published: 12 May 2021
Summary
CVE-2021-27385 is a high-severity Uncontrolled Resource Consumption (CWE-400) vulnerability in Siemens Simatic Hmi Comfort Outdoor Panels 15\" Firmware. Its CVSS base score is 7.5 (High).
Operationally, ranked in the top 33.2% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2021-14140
Vulnerability details
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16…
more
Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4), SINAMICS GH150 (All versions), SINAMICS GL150 (with option X30) (All versions), SINAMICS GM150 (with option X30) (All versions), SINAMICS SH150 (All versions), SINAMICS SL150 (All versions), SINAMICS SM120 (All versions), SINAMICS SM150 (All versions), SINAMICS SM150i (All versions). A remote attacker could send specially crafted packets to SmartVNC device layout handler on client side, which could influence the amount of resources consumed and result in a Denial-of-Service (infinite loop) condition.
- CWE(s)
Related Threats
No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.
Affected Assets
Mitigating Controls
Likely Mitigating Controls AI
Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.
Alternate site allows resumption of operations if resource exhaustion at the primary site is exploited to cause unavailability.
Directly limits uncontrolled resource consumption that leads to denial-of-service.
Limiting concurrent sessions directly prevents uncontrolled resource consumption by capping the number of active sessions per user or account.
Analysis identifies uncontrolled resource consumption indicative of denial-of-service or abuse attempts.
Contingency plan testing includes resource exhaustion scenarios to verify recovery, making it harder for attackers to sustain exploits that cause uncontrolled consumption.
Updated contingency plans include current procedures to detect, contain, and recover from resource exhaustion, limiting an attacker's ability to sustain impact from uncontrolled consumption.
Alternate telecommunications services enable resumption of essential functions when primary services become unavailable due to uncontrolled resource consumption.
The team can analyze and respond to resource exhaustion incidents, reducing the impact of attacks that exploit uncontrolled consumption weaknesses.