Cyber Resilience

CVE-2021-31340

HighDDoS

Published: 08 June 2021

Published
08 June 2021
Modified
21 November 2024
KEV Added
Patch
CVSS Score v3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS Score 0.0048 65.6th percentile
Risk Priority 15 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2021-31340 is a high-severity Uncontrolled Resource Consumption (CWE-400) vulnerability in Siemens Simatic Rf166C Firmware. Its CVSS base score is 7.5 (High).

Operationally, ranked in the top 34.4% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.

EU & UK References

Vulnerability details

A vulnerability has been identified in SIMATIC RF166C (All versions > V1.1 and < V1.3.2), SIMATIC RF185C (All versions > V1.1 and < V1.3.2), SIMATIC RF186C (All versions > V1.1 and < V1.3.2), SIMATIC RF186CI (All versions > V1.1 and…

more

< V1.3.2), SIMATIC RF188C (All versions > V1.1 and < V1.3.2), SIMATIC RF188CI (All versions > V1.1 and < V1.3.2), SIMATIC RF360R (All versions < V2.0), SIMATIC Reader RF610R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF610R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF610R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF615R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF615R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF615R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF650R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF650R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF650R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF680R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF680R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF680R FCC (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ARIB (All versions > V3.0 < V4.0), SIMATIC Reader RF685R CMIIT (All versions > V3.0 < V4.0), SIMATIC Reader RF685R ETSI (All versions > V3.0 < V4.0), SIMATIC Reader RF685R FCC (All versions > V3.0 < V4.0). Affected devices do not properly handle large numbers of incoming connections. An attacker may leverage this to cause a Denial-of-Service situation.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

siemens
simatic rf166c firmware
1.1 — 1.3.2
siemens
simatic rf185c firmware
1.1 — 1.3.2
siemens
simatic rf186c firmware
1.1 — 1.3.2
siemens
simatic rf186ci firmware
1.1 — 1.3.2
siemens
simatic rf188c firmware
1.1 — 1.3.2
siemens
simatic rf188ci firmware
1.1 — 1.3.2
siemens
simatic rf360r firmware
≤ 2.0
siemens
simatic reader rf610r cmiit firmware
3.0 — 4.0
siemens
simatic reader rf610r etsi firmware
3.0 — 4.0
siemens
simatic reader rf610r fcc firmware
3.0 — 4.0
+15 more product configuration(s) — see NVD for full list

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-400

Limiting concurrent sessions directly prevents uncontrolled resource consumption by capping the number of active sessions per user or account.

addresses: CWE-400

Analysis identifies uncontrolled resource consumption indicative of denial-of-service or abuse attempts.

addresses: CWE-400

Contingency plan testing includes resource exhaustion scenarios to verify recovery, making it harder for attackers to sustain exploits that cause uncontrolled consumption.

addresses: CWE-400

Updated contingency plans include current procedures to detect, contain, and recover from resource exhaustion, limiting an attacker's ability to sustain impact from uncontrolled consumption.

addresses: CWE-400

Alternate site allows resumption of operations if resource exhaustion at the primary site is exploited to cause unavailability.

addresses: CWE-400

Alternate telecommunications services enable resumption of essential functions when primary services become unavailable due to uncontrolled resource consumption.

addresses: CWE-400

The team can analyze and respond to resource exhaustion incidents, reducing the impact of attacks that exploit uncontrolled consumption weaknesses.

addresses: CWE-400

Timely maintenance support and spare parts enable rapid recovery from failures induced by uncontrolled resource consumption, shortening the impact window of denial-of-service attacks.

References