Cyber Resilience

CVE-2021-43283

HighPublic PoCRCE

Published: 30 November 2021

Published
30 November 2021
Modified
21 November 2024
KEV Added
Patch
CVSS Score v3.1 8.8 CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
EPSS Score 0.0660 91.4th percentile
Risk Priority 22 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2021-43283 is a high-severity OS Command Injection (CWE-78) vulnerability in Govicture Wr1200 Firmware. Its CVSS base score is 8.8 (High).

Operationally, ranked in the top 8.6% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog; a public proof-of-concept is referenced.

EU & UK References

Vulnerability details

An issue was discovered on Victure WR1200 devices through 1.0.3. A command injection vulnerability was found within the web interface of the device, allowing an attacker with valid credentials to inject arbitrary shell commands to be executed by the device…

more

with root privileges. This occurs in the ping and traceroute features. An attacker would thus be able to use this vulnerability to open a reverse shell on the device with root privileges.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

govicture
wr1200 firmware
≤ 1.0.3

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-78

Platform-independent apps typically execute inside a managed runtime or sandbox that restricts direct OS command execution, reducing the ability to exploit OS command injection.

addresses: CWE-78

Validates inputs to block special elements that would alter OS command execution.

References