Cyber Resilience

CVE-2022-22180

High

Published: 19 January 2022

Published
19 January 2022
Modified
21 November 2024
KEV Added
Patch
CVSS Score v3.1 7.5 CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
EPSS Score 0.0039 60.4th percentile
Risk Priority 15 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2022-22180 is a high-severity Improper Check for Unusual or Exceptional Conditions (CWE-754) vulnerability in Juniper Junos. Its CVSS base score is 7.5 (High).

Operationally, ranked in the top 39.6% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.

EU & UK References

Vulnerability details

An Improper Check for Unusual or Exceptional Conditions vulnerability in the processing of specific IPv6 packets on certain EX Series devices may lead to exhaustion of DMA memory causing a Denial of Service (DoS). Over time, exploitation of this vulnerability…

more

may cause traffic to stop being forwarded, or a crash of the fxpc process. An indication of the issue occurring may be observed through the following log messages: Sep 13 17:14:59 hostname : %PFE-3: fpc0 (buf alloc) failed allocating packet buffer Sep 13 17:14:59 hostname : %PFE-7: fpc0 brcm_pkt_buf_alloc:393 (buf alloc) failed allocating packet buffer When Packet DMA heap utilization reaches 99%, the system will become unstable. Packet DMA heap utilization can be monitored using the command: user@junos# request pfe execute target fpc0 timeout 30 command "show heap" ID Base Total(b) Free(b) Used(b) % Name -- ---------- ----------- ----------- ----------- --- ----------- 0 213301a8 536870488 387228840 149641648 27 Kernel 1 91800000 8388608 3735120 4653488 55 DMA 2 92000000 75497472 74452192 1045280 1 PKT DMA DESC 3 d330000 335544320 257091400 78452920 23 Bcm_sdk 4 96800000 184549376 2408 184546968 99 Packet DMA <<<< 5 903fffe0 20971504 20971504 0 0 Blob This issue affects: Juniper Networks Junos OS 18.4 versions prior to 18.4R2-S10, 18.4R3-S10 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.1 versions prior to 19.1R3-S7 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.2 versions prior to 19.2R1-S8, 19.2R3-S4 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.3 versions prior to 19.3R3-S5 on EX2300 Series, EX2300-MP Series, EX3400 Series; 19.4 versions prior to 19.4R3-S7 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.1 versions prior to 20.1R3-S3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.2 versions prior to 20.2R3-S3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.3 versions prior to 20.3R3-S2 on EX2300 Series, EX2300-MP Series, EX3400 Series; 20.4 versions prior to 20.4R3-S1 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.1 versions prior to 21.1R2-S2, 21.1R3 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.2 versions prior to 21.2R1-S2, 21.2R2 on EX2300 Series, EX2300-MP Series, EX3400 Series; 21.3 versions prior to 21.3R1-S1, 21.3R2 on EX2300 Series, EX2300-MP Series, EX3400 Series.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

juniper
junos
18.4, 19.1, 19.2, 19.3, 19.4

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-754

Requires detection and response to audit logging failures as an unusual or exceptional condition.

addresses: CWE-754

Implements detection of unusual or exceptional conditions followed by safe mode entry, reducing the window for exploitation of unchecked conditions.

addresses: CWE-754

Training ensures users perform required checks for unusual or exceptional conditions as part of contingency roles, limiting attacker leverage from skipped validations.

addresses: CWE-754

IR testing directly validates checks for unusual or exceptional conditions that could indicate security incidents.

addresses: CWE-754

Requires ongoing monitoring of organization-defined metrics and analysis, enabling checks for unusual or exceptional conditions.

addresses: CWE-754

Security testing routinely checks for unusual or exceptional inputs/conditions, identifying missing validation steps that flaw remediation then resolves.

addresses: CWE-754

Requires detection of unusual conditions followed by a controlled transition to the defined failure state.

addresses: CWE-754

MTTF determination forces explicit checks for conditions that precede predictable component failure.

References