CVE-2022-22806 is a critical-severity Authentication Bypass by Capture-replay (CWE-294) vulnerability in Schneider-Electric Smt Series 1015 Ups Firmware. Its CVSS base score is 9.8 (Critical).

Operationally, ranked at the 45.5th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

EU & UK References

Vulnerability details

A CWE-294: Authentication Bypass by Capture-replay vulnerability exists that could cause an unauthenticated connection to the UPS when a malformed connection is sent. Affected Product: SmartConnect Family: SMT Series (SMT Series ID=1015: UPS 04.5 and prior), SMC Series (SMC Series…

more

ID=1018: UPS 04.2 and prior), SMTL Series (SMTL Series ID=1026: UPS 02.9 and prior), SCL Series (SCL Series ID=1029: UPS 02.5 and prior / SCL Series ID=1030: UPS 02.5 and prior / SCL Series ID=1036: UPS 02.5 and prior / SCL Series ID=1037: UPS 03.1 and prior), SMX Series (SMX Series ID=1031: UPS 03.1 and prior)

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

schneider-electric
smt series 1015 ups firmware
≤ 04.5
schneider-electric
smc series 1018 ups firmware
≤ 04.2
schneider-electric
smtl series 1026 ups firmware
≤ 02.9
schneider-electric
scl series 1029 ups firmware
≤ 02.5
schneider-electric
scl series 1030 ups firmware
≤ 02.5
schneider-electric
scl series 1036 ups firmware
≤ 02.5
schneider-electric
scl series 1037 ups firmware
≤ 03.1
schneider-electric
smx series 1031 ups firmware
≤ 03.1

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-294

Allows detection of capture-replay attacks by showing the replayed logon's timestamp as the last logon.

addresses: CWE-294

Protects against replay of captured session tokens or credentials by requiring authenticated, fresh session channels.

addresses: CWE-294

Wireless link protections commonly incorporate replay protection, reducing the exploitability of capture-replay weaknesses.

addresses: CWE-294

Accurate synchronized time enables tight timestamp windows that directly limit capture-replay windows in authentication protocols.

References