CVE-2022-41969

Low

Published: 01 December 2022

Published
01 December 2022
Modified
21 November 2024
KEV Added
Patch
CVSS Score v3.1 2.4 CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:N/I:N/A:L
EPSS Score 0.0033 56.4th percentile
Risk Priority 5 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2022-41969 is a low-severity Uncontrolled Resource Consumption (CWE-400) vulnerability in Nextcloud Nextcloud Server. Its CVSS base score is 2.4 (Low).

Operationally, ranked in the top 43.6% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.

EU & UK References

Vulnerability details

Nextcloud Server is an open source personal cloud server. Prior to versions 23.0.11, 24.0.7, and 25.0.0, there is no password length limit when creating a user as an administrator. An administrator can cause a limited DoS attack against their own…

more

server. Versions 23.0.11, 24.0.7, and 25.0.0 contain a fix for the issue. As a workaround, don't create user accounts with long passwords.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

nextcloud
nextcloud server
23.0.0 — 23.0.11 · 23.0.0 — 23.0.11 · 24.0.0 — 24.0.7

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-400

Limiting concurrent sessions directly prevents uncontrolled resource consumption by capping the number of active sessions per user or account.

addresses: CWE-400

Analysis identifies uncontrolled resource consumption indicative of denial-of-service or abuse attempts.

addresses: CWE-521

Configuration settings can define and enforce strong password requirements to avoid weak policies.

addresses: CWE-400

Contingency plan testing includes resource exhaustion scenarios to verify recovery, making it harder for attackers to sustain exploits that cause uncontrolled consumption.

addresses: CWE-400

Updated contingency plans include current procedures to detect, contain, and recover from resource exhaustion, limiting an attacker's ability to sustain impact from uncontrolled consumption.

addresses: CWE-400

Alternate site allows resumption of operations if resource exhaustion at the primary site is exploited to cause unavailability.

addresses: CWE-400

Alternate telecommunications services enable resumption of essential functions when primary services become unavailable due to uncontrolled resource consumption.

addresses: CWE-521

IA policy establishes password requirements, directly addressing weak password requirements.