Summary

CVE-2022-43990 is a high-severity Missing Authentication for Critical Function (CWE-306) vulnerability in Sick Sim1012-0P0G200 Firmware. Its CVSS base score is 7.3 (High).

Operationally, ranked in the top 36.0% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.

EU & UK References

Vulnerability details

Password recovery vulnerability in SICK SIM1012 Partnumber 1098146 with firmware version <2.2.0 allows an unprivileged remote attacker to gain access to the userlevel defined as RecoverableUserLevel by invocating the password recovery mechanism method. This leads to an increase in their…

more

privileges on the system and thereby affecting the confidentiality integrity and availability of the system. An attacker can expect repeatable success by exploiting the vulnerability. The recommended solution is to update the firmware to a version >= 2.2.0 as soon as possible (available in SICK Support Portal).

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

sick
sim1012-0p0g200 firmware
≤ 2.2.0

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-306

Requires established identification and authentication to unlock, mitigating missing authentication for continued system access.

addresses: CWE-306

Requiring identification and rationale for actions allowed without authentication ensures critical functions are not left unprotected by forcing review of authentication requirements.

addresses: CWE-306

Authorizing mobile device connections to organizational systems ensures authentication is performed for this critical access function.

addresses: CWE-306

Guarantees critical functions are protected by mandatory invocation of the access control mechanism.

addresses: CWE-306

Auditing sessions makes it possible to detect access to critical functions without required authentication.

addresses: CWE-306

The assessment process confirms authentication is present and effective for critical functions, preventing exploitation from missing authentication.

addresses: CWE-306

Certification assesses that critical functions have required authentication controls in place.

addresses: CWE-306

Disabling non-essential functions and services eliminates the need to secure them, reducing exposure from missing authentication on unnecessary components.

References