Security Resilience

CVE-2023-52951

Synology Note Station Client ≤ 2.2.4-703

Published
03 June 2026
Modified
22 July 2026
CVSS Score v3.1 5.9
Click a component to see what it means
Raw vectorCVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:N/A:N
EPSS Score 0.0013 2th percentile
Risk Priority 43 floored blend · peak EPSS

CVSS and EPSS are reproduced from their sources (NVD, FIRST EPSS). Risk Priority is our own derived reading, not an NVD score.

Summary

CVE-2023-52951 is a medium-severity Cleartext Transmission of Sensitive Information (CWE-319) vulnerability in Synology Note Station Client. Its CVSS base score is 5.9 (Medium).

Operationally, exploitation aligns with the MITRE ATT&CK technique Network Sniffing (T1040); ranked at the 2th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

The strongest mitigations our analysis identified map to SC-8 (Transmission Confidentiality and Integrity) — see the control section below for these in your framework.

OWASP Top 10 for Web (2025)

EU & UK References

Vulnerability Data

A cleartext transmission of sensitive information vulnerability in Synology Note Station Client before 2.2.4-703 allows man-in-the-middle attackers to obtain user credential.

CWE(s)

Related Threats

MITRE ATT&CK Enterprise Techniques

T1040 Network Sniffing Credential Access
Adversaries may passively sniff network traffic to capture information about an environment, including authentication material passed over the network.
T1003.004 LSA Secrets Credential Access
Adversaries with SYSTEM access to a host may attempt to access Local Security Authority (LSA) secrets, which can contain a variety of different credential materials, such as credentials for service accounts.
T1003.008 /etc/passwd and /etc/shadow Credential Access
Adversaries may attempt to dump the contents of <code>/etc/passwd</code> and <code>/etc/shadow</code> to enable offline password cracking.
T1006 Direct Volume Access Stealth
Adversaries may directly access a volume to bypass file access controls and file system monitoring.
T1007 System Service Discovery Discovery
Adversaries may try to gather information about registered local system services.
T1010 Application Window Discovery Discovery
Adversaries may attempt to get a listing of open application windows.
Derived from this CVE’s CWE(s) via the direct CWE→ATT&CK cross-walk.

CVEs Like This One

CVE-2024-47269Same product class: NAS / storage appliance
CVE-2024-11946Same product class: NAS / storage appliance
CVE-2023-23915Same product class: NAS / storage appliance
CVE-2023-34972Same product class: NAS / storage appliance
CVE-2023-23914Same product class: NAS / storage appliance
CVE-2024-4464Same product class: NAS / storage appliance
CVE-2025-12686Same product class: NAS / storage appliance
CVE-2023-52946Same product class: NAS / storage appliance
CVE-2024-5463Same product class: NAS / storage appliance
CVE-2023-5748Same product class: NAS / storage appliance

Affected Assets

synology
note station client
≤ 2.2.4-703

Mitigating Controls

Mitigating Controls (NIST 800-53 r5) AI

SC-8 directly requires protecting confidentiality of transmitted information, which structurally eliminates cleartext transmission of sensitive data.

Mitigating Controls (NIST CSF 2.0) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.

PR.DS-02 partial match
blocks

Encryption of data-in-transit directly prevents cleartext transmission while the control also addresses integrity and availability.

Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.

blocks

Mandating cryptographic protection and stronger authentication on public networks stops the transmission of plaintext sensitive information.

removes
removes
removes
removes

References