Cyber Resilience

CVE-2024-22045

High

Published: 12 March 2024

Published
12 March 2024
Modified
21 November 2024
KEV Added
Patch
CVSS Score v3.1 7.6 CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:H/I:L/A:N
EPSS Score 0.0036 58.2th percentile
Risk Priority 15 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2024-22045 is a high-severity Insertion of Sensitive Information into Externally-Accessible File or Directory (CWE-538) vulnerability in Siemens Sinema Remote Connect Client. Its CVSS base score is 7.6 (High).

Operationally, ranked in the top 41.8% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.

EU & UK References

Vulnerability details

A vulnerability has been identified in SINEMA Remote Connect Client (All versions < V3.1 SP1). The product places sensitive information into files or directories that are accessible to actors who are allowed to have access to the files, but not…

more

to the sensitive information. This information is also available via the web interface of the product.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

siemens
sinema remote connect client
3.1 · ≤ 3.1

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-538

Pre- and post-publication reviews prevent insertion of sensitive information into externally-accessible public locations.

addresses: CWE-538

Monitors for sensitive information placed in externally accessible files or directories.

addresses: CWE-538

The map shows if data actions result in sensitive information being placed in externally accessible locations.

addresses: CWE-538

Isolation and eradication reduce the ability to exploit sensitive information inserted into externally-accessible files or directories.

addresses: CWE-538

Approved categorization forces identification of externally accessible files that contain sensitive content so they receive proper protection.

addresses: CWE-538

The pre-implementation review identifies externally accessible files or directories containing PII and drives access restrictions or removal.

addresses: CWE-538

Tainting makes it possible to determine when sensitive data has been removed from externally accessible files or directories.

addresses: CWE-538

OPSEC practices stop placement of supply-chain information into locations accessible to external parties.

References