Security Resilience

CVE-2024-45229

Access Control in Versa-Networks Versa Director 21.2.2 … 22.1.4

Published
20 September 2024
Modified
25 August 2026
Patch / advisory
CVSS Score v3 6.6
Click a component to see what it means
Raw vectorCVSS:3.0/AV:N/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H
EPSS Score 0.0051 42th percentile
Risk Priority 49 floored blend · peak EPSS

CVSS and EPSS are reproduced from their sources (NVD, FIRST EPSS). Risk Priority is our own derived reading, not an NVD score.

Summary

CVE-2024-45229 is a medium-severity Missing Authentication for Critical Function (CWE-306) vulnerability in Versa-Networks Versa Director. Its CVSS base score is 6.6 (Medium).

Operationally, exploitation aligns with the MITRE ATT&CK technique Steganography (T1001.002); ranked at the 42th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

The strongest mitigations our analysis identified map to AC-14 (Permitted Actions Without Identification or Authentication) and IA-2 (Identification and Authentication (Organizational Users)) — see the control section below for these in your framework.

OWASP Top 10 for Web (2025)

EU & UK References

Vulnerability Data

The Versa Director offers REST APIs for orchestration and management. By design, certain APIs, such as the login screen, banner display, and device registration, do not require authentication. However, it was discovered that for Directors directly connected to the Internet,…

more

one of these APIs can be exploited by injecting invalid arguments into a GET request, potentially exposing the authentication tokens of other currently logged-in users. These tokens can then be used to invoke additional APIs on port 9183. This exploit does not disclose any username or password information. Currently, there are no workarounds in Versa Director. However, if there is Web Application Firewall (WAF) or API Gateway fronting the Versa Director, it can be used to block access to the URLs of vulnerable API. /vnms/devicereg/device/* (on ports 9182 & 9183) and /versa/vnms/devicereg/device/* (on port 443). Versa recommends that Directors be upgraded to one of the remediated software versions. This vulnerability is not exploitable on Versa Directors not exposed to the Internet.We have validated that no Versa-hosted head ends have been affected by this vulnerability. Please contact Versa Technical Support or Versa account team for any further assistance.

CWE(s)

Related Threats

MITRE ATT&CK Enterprise Techniques

T1001.002 Steganography Command And Control
Adversaries may use steganographic techniques to hide command and control traffic to make detection efforts more difficult.
T1007 System Service Discovery Discovery
Adversaries may try to gather information about registered local system services.
T1010 Application Window Discovery Discovery
Adversaries may attempt to get a listing of open application windows.
T1016 System Network Configuration Discovery Discovery
Adversaries may look for details about the network configuration and settings, such as IP and/or MAC addresses, of systems they access or through information discovery of remote systems.
T1021.002 SMB/Windows Admin Shares Lateral Movement
Adversaries may use [Valid Accounts](https://attack.
T1027.004 Compile After Delivery Stealth
Adversaries may attempt to make payloads difficult to discover and analyze by delivering files to victims as uncompiled code.
Derived from this CVE’s CWE(s) via the direct CWE→ATT&CK cross-walk.

CVEs Like This One

CVE-2025-24288Same product: Versa-Networks Versa Director
CVE-2025-23168Same product: Versa-Networks Versa Director
CVE-2024-42450Same product: Versa-Networks Versa Director
CVE-2025-23171Same product: Versa-Networks Versa Director
CVE-2024-39717Same product: Versa-Networks Versa Director
CVE-2025-23169Same product: Versa-Networks Versa Director
CVE-2025-23172Same product: Versa-Networks Versa Director
CVE-2025-24291Same product: Versa-Networks Versa Director
CVE-2025-23170Same product: Versa-Networks Versa Director
CVE-2025-23173Same product: Versa-Networks Versa Director

Affected Assets

versa-networks
versa director
21.2.2, 21.2.3, 22.1.1, 22.1.2, 22.1.3

Mitigating Controls

Control response

Prevent
Stop it (NIST 800-53)

—

Detect
Catch it (NIST detect / respond)

—

Harden
Shrink the surface (DISA STIG)
  • 6 hardening rules · 3 OS baselines
Validate
Prove the fix (OWASP ASVS)
  • V6.2.3
  • V6.4.4
  • V10.4.16
  • V12.1.3

Mitigating Controls (NIST 800-53 r5) AI

Directly mandates unique identification and authentication of users before access to functions requiring identity.

Extends the same authentication requirement to non-organizational users accessing critical functionality.

Requires authentication of services before they can invoke or expose critical functions.

Explicitly identifies and limits actions permitted without authentication, preventing critical functions from being exposed.

Access enforcement requires prior authentication before any authorization decision for critical functions.

Mitigating Controls (NIST CSF 2.0) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.

PR.AA-01 partial match
blocks

Managing identities and credentials is a prerequisite for authentication but does not itself enforce it on critical functions.

PR.AA-03 partial match
blocks

Directly requires authentication of users/services/hardware, which eliminates missing authentication for critical functions.

PR.AA-05 partial match
blocks

Defining and enforcing authorizations assumes prior authentication and therefore only partially mitigates the absence of authentication.

PR.IR-01 partial match
blocks

Protecting networks from unauthorized access can be undermined by missing authentication but does not address the root authentication gap.

Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.

removes
removes
removes
blocks

Mandating authentication requirements for critical functions at the requirements-gathering stage ensures that essential operations are not left unprotected by missing login or verification mechanisms.

removes

Hardening callouts derived

Configuration rules from DISA STIG baselines that bear on weaknesses of the type cited by this CVE. Each rule is shown with the relationship its mapping actually records, against the CWE it was authored against. Derived via CVE→CWE over `controls_xwalks` (higher-evidence rows only; rows rated `none` are excluded).

Oracle Linux 8 (2 rules)
  • V-248585 OL 8 must require reauthentication when using the "sudo" command. blocks CWE-306
  • V-248827 OL 8 must not have the rsh-server package installed. blocks CWE-306
RHEL 7 (2 rules)
  • V-204442 The Red Hat Enterprise Linux operating system must not have the rsh-server package installed. blocks CWE-306
  • V-237635 The Red Hat Enterprise Linux operating system must require re-authentication when using the "sudo" command. blocks CWE-306
RHEL 8 (2 rules)
  • V-230492 RHEL 8 must not have the rsh-server package installed. blocks CWE-306
  • V-237643 RHEL 8 must require re-authentication when using the "sudo" command. blocks CWE-306

References