Cyber Resilience

CVE-2025-40773

Access Control in Siemens Sipass Integrated ≤ 3.00

Published
14 October 2025
Modified
16 October 2025
Patch / advisory
CVSS Score v4 5.1
Click a component to see what it means
Raw vectorCVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS Score 0.0018 8th percentile
Risk Priority 26 floored blend · peak EPSS

Summary

CVE-2025-40773 is a medium-severity Authorization Bypass Through User-Controlled Key (CWE-639) vulnerability in Siemens Sipass Integrated. Its CVSS base score is 5.1 (Medium).

Operationally, exploitation aligns with the MITRE ATT&CK technique Exploit Public-Facing Application (T1190); ranked at the 8th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

The strongest mitigations our analysis identified map to AC-24 (Access Control Decisions) and AC-3 (Access Enforcement) — see the control section below for these in your framework.

OWASP Top 10 for Web (2025)

EU & UK References

Vulnerability Data

A vulnerability has been identified in SiPass integrated (All versions < V3.0). Affected server applications contains a broken access control vulnerability. The authorization mechanism lacks sufficient server-side checks, allowing an attacker to execute a specific API request. Successful exploitation allows…

more

an attacker to potentially manipulate data belonging to other users.

CWE(s)

Related Threats

MITRE ATT&CK Enterprise Techniques

T1190 Exploit Public-Facing Application Initial Access
Adversaries may attempt to exploit a weakness in an Internet-facing host or system to initially access a network.
Derived from this CVE’s CWE(s) via the direct CWE→ATT&CK cross-walk.

CVEs Like This One

CVE-2025-40772Same product: Siemens Sipass Integrated
CVE-2023-49251Same vendor: Siemens
CVE-2025-40774Same product: Siemens Sipass Integrated
CVE-2025-32862Same vendor: Siemens
CVE-2025-32849Same vendor: Siemens
CVE-2025-31350Same vendor: Siemens
CVE-2025-40755Same vendor: Siemens
CVE-2024-39870Same vendor: Siemens
CVE-2024-27946Same vendor: Siemens
CVE-2025-32844Same vendor: Siemens

Affected Assets

siemens
sipass integrated
≤ 3.00

Mitigating Controls

Mitigating Controls (NIST 800-53 r5) AI

Enforcing approved authorizations on every access request structurally stops a user-controlled key from reaching another user's data.

Requiring explicit access-control decisions on each request blocks unauthorized key-driven access.

Least-privilege restrictions limit the scope of data reachable even if a key check is bypassed.

Mitigating Controls (NIST CSF 2.0) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.

PR.AA-05 full match
prevents

Enforcing authorization policy and least privilege directly blocks user-controlled key tampering that bypasses access checks.

PR.IR-01 mostly match
prevents

Logical access controls prevent unauthorized data access that results from missing authorization checks on object references.

Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.

finds

Security testing can detect missing authorization checks but does not prevent the weakness in production.

prevents

Information access restriction explicitly enforces that users may only retrieve data they are authorized to see, directly addressing user-controlled key bypass.

prevents

Access control policy directly requires enforcement of authorization rules that prevent unauthorized access via manipulated keys.

prevents

Managing access rights includes ensuring users can only access their own records and not bypass authorization by altering identifiers.

mitigates

Privileged access rights control restricts what data each user may access, mitigating direct object reference attacks.

prevents

Secure development lifecycle includes authorization design but does not itself implement runtime access checks.

References