CVSS Score v3.1 6.1 CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N
EPSS Score 0.1146 93.8th percentile
Risk Priority 19 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2021-20137 is a medium-severity Cross-site Scripting (CWE-79) vulnerability in Gryphonconnect Gryphon Tower Firmware. Its CVSS base score is 6.1 (Medium).

Operationally, ranked in the top 6.2% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog; a public proof-of-concept is referenced.

EU & UK References

Vulnerability details

A reflected cross-site scripting vulnerability exists in the url parameter of the /cgi-bin/luci/site_access/ page on the Gryphon Tower router's web interface. An attacker could exploit this issue by tricking a user into following a specially crafted link, granting the attacker…

more

javascript execution in the context of the victim's browser.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

gryphonconnect
gryphon tower firmware
≤ 04.0004.12

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-79

Penetration testing submits XSS payloads to web applications, detecting cross-site scripting flaws for subsequent remediation.

addresses: CWE-79

Validates web inputs to reject script-related content that could produce XSS.

addresses: CWE-79

Output validation against expected content can reject or sanitize script content in generated web pages, reducing XSS exploitability.