CVE-2021-25662
Published: 12 May 2021
Summary
CVE-2021-25662 is a high-severity Improper Handling of Exceptional Conditions (CWE-755) vulnerability in Siemens Simatic Hmi Comfort Outdoor Panels 15\" Firmware. Its CVSS base score is 7.5 (High).
Operationally, ranked in the top 26.6% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2021-12554
Vulnerability details
A vulnerability has been identified in SIMATIC HMI Comfort Outdoor Panels V15 7\" & 15\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Outdoor Panels V16 7\" & 15\" (incl. SIPLUS variants) (All versions < V16…
more
Update 4), SIMATIC HMI Comfort Panels V15 4\" - 22\" (incl. SIPLUS variants) (All versions < V15.1 Update 6), SIMATIC HMI Comfort Panels V16 4\" - 22\" (incl. SIPLUS variants) (All versions < V16 Update 4), SIMATIC HMI KTP Mobile Panels V15 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V15.1 Update 6), SIMATIC HMI KTP Mobile Panels V16 KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions < V16 Update 4), SIMATIC WinCC Runtime Advanced V15 (All versions < V15.1 Update 6), SIMATIC WinCC Runtime Advanced V16 (All versions < V16 Update 4). SmartVNC client fails to handle an exception properly if the program execution process is modified after sending a packet from the server, which could result in a Denial-of-Service condition.
- CWE(s)
Related Threats
No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.
Affected Assets
Mitigating Controls
Likely Mitigating Controls AI
Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.
Provides defined handling (alert and additional actions) for the exceptional condition of audit logging failure.
Supplies a concrete handling action (safe mode) for exceptional conditions, mitigating risks from improper or absent handling that could allow continued attacks.
By preparing users for contingency scenarios, the control promotes proper handling of exceptional conditions instead of default or unsafe behaviors.
An updated contingency plan defines current actions for exceptional conditions, reducing the window for attackers to exploit improper handling leading to system failure.
Procedures ensure proper handling of exceptional conditions to support effective incident response.
Incident response testing confirms proper handling of exceptional conditions to limit exploit impact.
Gives users guidance on incident handling, reducing improper handling of exceptional conditions that could stem from exploited weaknesses.
Enforces structured response to exceptional conditions so the system cannot remain in an unsafe state.