Summary

CVE-2022-46144 is a high-severity Improper Control of a Resource Through its Lifetime (CWE-664) vulnerability in Siemens 6Gk5622-2Gs00-2Ac2 Firmware. Its CVSS base score is 7.1 (High).

Operationally, ranked in the top 25.1% of CVEs by exploit likelihood; it is not currently listed in the CISA KEV catalog.

EU & UK References

Vulnerability details

A vulnerability has been identified in SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions < V2.3), SCALANCE SC622-2C (6GK5622-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions < V2.3), SCALANCE SC626-2C (6GK5626-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC632-2C…

more

(6GK5632-2GS00-2AC2) (All versions < V2.3), SCALANCE SC632-2C (6GK5632-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions < V2.3), SCALANCE SC636-2C (6GK5636-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions < V2.3), SCALANCE SC642-2C (6GK5642-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions < V2.3), SCALANCE SC646-2C (6GK5646-2GS00-2AC2) (All versions >= V2.3 < V3.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V2.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V2.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V2.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V2.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V2.0.0). Affected devices do not properly process CLI commands after a user forcefully quitted the SSH connection. This could allow an authenticated attacker to make the CLI via SSH or serial interface irresponsive.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

siemens
6gk5622-2gs00-2ac2 firmware
2.3 — 3.0 · ≤ 2.3
siemens
6gk5626-2gs00-2ac2 firmware
2.3 — 3.0 · ≤ 2.3
siemens
6gk5632-2gs00-2ac2 firmware
2.3 — 3.0 · ≤ 2.3
siemens
6gk5636-2gs00-2ac2 firmware
2.3 — 3.0 · ≤ 2.3
siemens
6gk5642-2gs00-2ac2 firmware
2.3 — 3.0 · ≤ 2.3
siemens
6gk5646-2gs00-2ac2 firmware
2.3 — 3.0 · ≤ 2.3

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-664

Requires a managed development lifecycle process with integrity controls on changes, improving control of resources throughout their lifetime.

addresses: CWE-664

Requires designing resource lifetime controls that anticipate, withstand, and recover from stresses or attacks, mitigating improper resource control.

addresses: CWE-664

Directly enforces limited resource lifetime by requiring initiation from a known state and explicit termination, shrinking the window any long-lived resource weakness can be exploited.