Security Resilience

CVE-2023-45741

Command Injection in Buffalo Vr-S1000 Firmware ≤ 2.37

Published
26 December 2023
Modified
21 November 2024
Patch / advisory
CVSS Score v3.1 6.8
Click a component to see what it means
Raw vectorCVSS:3.1/AV:A/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
EPSS Score 0.0033 24th percentile
Risk Priority 50 floored blend · peak EPSS

CVSS and EPSS are reproduced from their sources (NVD, FIRST EPSS). Risk Priority is our own derived reading, not an NVD score.

Summary

CVE-2023-45741 is a medium-severity OS Command Injection (CWE-78) vulnerability in Buffalo Vr-S1000 Firmware. Its CVSS base score is 6.8 (Medium).

Operationally, exploitation aligns with the MITRE ATT&CK technique NTDS (T1003.003); ranked at the 24th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

OWASP Top 10 for Web (2025)

EU & UK References

Vulnerability Data

VR-S1000 firmware Ver. 2.37 and earlier allows an attacker with access to the product's web management page to execute arbitrary OS commands.

CWE(s)

Related Threats

MITRE ATT&CK Enterprise Techniques

T1003.003 NTDS Credential Access
Adversaries may attempt to access or create a copy of the Active Directory domain database in order to steal credential information, as well as obtain other information about domain members such as devices, users, and access rights.
T1007 System Service Discovery Discovery
Adversaries may try to gather information about registered local system services.
T1010 Application Window Discovery Discovery
Adversaries may attempt to get a listing of open application windows.
T1021.004 SSH Lateral Movement
Adversaries may use [Valid Accounts](https://attack.
T1021.008 Direct Cloud VM Connections Lateral Movement
Adversaries may leverage [Valid Accounts](https://attack.
T1027.001 Binary Padding Stealth
Adversaries may use binary padding to add junk data and change the on-disk representation of malware.
Derived from this CVE’s CWE(s) via the direct CWE→ATT&CK cross-walk.

CVEs Like This One

CVE-2026-45777Same vendor: Buffalo
CVE-2026-27650Same vendor: Buffalo
CVE-2024-26023Same vendor: Buffalo
CVE-2023-49038Same vendor: Buffalo
CVE-2023-36670Shared CWE-78
CVE-2026-49255Shared CWE-78
CVE-2025-30286Shared CWE-78
CVE-2023-1082Shared CWE-78
CVE-2024-24333Shared CWE-78
CVE-2025-61304Shared CWE-78

Affected Assets

buffalo
vr-s1000 firmware
≤ 2.37

Mitigating Controls

Control response

Prevent
Stop it (NIST 800-53)

—

Detect
Catch it (NIST detect / respond)

—

Harden
Shrink the surface (DISA STIG)

—

Validate
Prove the fix (OWASP ASVS)
  • V1.2.5
  • V1.2.8

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-78

Platform-independent apps typically execute inside a managed runtime or sandbox that restricts direct OS command execution, reducing the ability to exploit OS command injection.

addresses: CWE-78

Validates inputs to block special elements that would alter OS command execution.

Mitigating Controls (NIST CSF 2.0) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→CSF cross-walk (authority under review) — links open the control.

PR.PS-06 mostly match
blocks

PR.PS-06's SDLC practices directly require secure coding and input handling that blocks command-injection defects, yet the single broad outcome leaves many specific neutralization vectors and verification gaps unaddressed.

PR.PS-02 partial match
blocks

Routine patching/maintenance can remediate known command-injection CVEs in dependencies (partial forward) but does nothing to stop developers from introducing improper neutralization in custom code (none reverse).

Mitigating Controls (ISO/IEC 27001:2022 Annex A) AI

Derived directly from the weakness types (CWEs) cited in the NVD entry via our AI-authored CWE→ISO cross-walk (authority under review) — links open the control.

removes
removes
removes
removes
removes

References