Cyber Resilience

CVE-2025-32828

High

Published: 16 April 2025

Published
16 April 2025
Modified
19 August 2025
KEV Added
Patch
CVSS Score v4 8.7 CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS Score 0.0004 12.5th percentile
Risk Priority 17 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2025-32828 is a high-severity SQL Injection (CWE-89) vulnerability in Siemens Telecontrol Server Basic. Its CVSS base score is 8.7 (High).

Operationally, ranked at the 12.5th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

Deeper analysis

CVE-2025-32828 is an SQL injection vulnerability in Siemens TeleControl Server Basic versions prior to V3.1.2.2. The flaw exists in the internally used UpdateProjectCrossCommunications method and stems from insufficient input sanitization, allowing crafted queries to reach the application's database.

An authenticated remote attacker who can reach TCP port 8000 on a host running the affected software can exploit the issue to bypass authorization checks, read from and write to the database, and execute operating-system commands under the NT AUTHORITY\NetworkService account. The CVSS 4.0 score of 8.7 reflects network attack vector, low attack complexity, and high impact on confidentiality, integrity, and availability.

The Siemens advisory at https://cert-portal.siemens.com/productcert/html/ssa-443402.html recommends upgrading to version V3.1.2.2 or later and restricting network access to port 8000 until the patch can be applied.

EPSS for the CVE rose from a low baseline to a recorded peak of 0.0100, indicating that exploitation interest appeared after disclosure and that the issue merits renewed monitoring.

EU & UK References

Vulnerability details

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UpdateProjectCrossCommunications' method. This could allow an authenticated remote attacker to bypass authorization controls, to read…

more

from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

siemens
telecontrol server basic
≤ 3.1.2.2

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-89

Penetration testing uses SQL injection payloads against database interfaces, identifying and supporting fixes for SQL injection weaknesses.

addresses: CWE-89

Validates query inputs to prevent SQL syntax or command manipulation.

References