Summary

CVE-2025-32853 is a high-severity SQL Injection (CWE-89) vulnerability in Siemens Telecontrol Server Basic. Its CVSS base score is 8.7 (High).

Operationally, ranked at the 17.4th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

Deeper analysis

A vulnerability has been identified in TeleControl Server Basic versions prior to V3.1.2.2 consisting of an SQL injection flaw in the internally used UnlockDatabaseSettings method. The affected component is the TeleControl Server Basic application, which listens on port 8000 and maintains its own database.

An authenticated remote attacker with network access to port 8000 can exploit the flaw to bypass authorization controls, read from and write to the application database, and execute code under the NT AUTHORITY\NetworkService account. The attack requires valid credentials but no user interaction and carries a CVSS 4.0 score of 8.7.

The Siemens advisory at https://cert-portal.siemens.com/productcert/html/ssa-443402.html addresses the issue by identifying all versions prior to V3.1.2.2 as vulnerable and directing users to apply the corrected release.

EPSS for the CVE rose from a low of 0.0005 to a peak of 0.0100, indicating that exploitation interest increased after disclosure.

EU & UK References

Vulnerability details

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'UnlockDatabaseSettings' method. This could allow an authenticated remote attacker to bypass authorization controls, to read…

more

from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.

CWE(s)

Related Threats

No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.

Affected Assets

siemens
telecontrol server basic
≤ 3.1.2.2

Mitigating Controls

Likely Mitigating Controls AI

Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.

addresses: CWE-89

Penetration testing uses SQL injection payloads against database interfaces, identifying and supporting fixes for SQL injection weaknesses.

addresses: CWE-89

Validates query inputs to prevent SQL syntax or command manipulation.