CVE-2025-32867
Published: 16 April 2025
Summary
CVE-2025-32867 is a high-severity SQL Injection (CWE-89) vulnerability in Siemens Telecontrol Server Basic. Its CVSS base score is 8.7 (High).
Operationally, ranked at the 14.5th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.
Deeper analysis
A vulnerability has been identified in TeleControl Server Basic versions prior to V3.1.2.2 consisting of an SQL injection flaw in the internally used CreateBackup method. The affected component allows an authenticated remote attacker with network access to port 8000 to bypass authorization controls, read from and write to the application database, and execute code under the NT AUTHORITY\NetworkService account. The issue is tracked as CWE-89 and carries a CVSS 4.0 score of 8.7 reflecting network attack vector, low complexity, and high impact on confidentiality, integrity, and availability.
An attacker who can reach the exposed port on a system running a vulnerable instance may leverage the injection to interact directly with the database and obtain code execution privileges equivalent to the NetworkService account. No user interaction or additional privileges beyond valid authentication are required for successful exploitation.
The Siemens advisory at cert-portal.siemens.com/productcert/html/ssa-443402.html recommends upgrading to version V3.1.2.2 or later to address the flaw and provides guidance on restricting network access to the affected service.
The associated EPSS score rose from a low of 0.0004 to a peak of 0.0100, indicating that exploitation interest increased after public disclosure.
EU & UK References
- 🇪🇺 ENISA EUVD: EUVD-2025-11400
Vulnerability details
A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateBackup' method. This could allow an authenticated remote attacker to bypass authorization controls, to read…
more
from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on.
- CWE(s)
Related Threats
No named actor attribution yet. ATT&CK technique mapping in progress for this CVE.
Affected Assets
Mitigating Controls
Likely Mitigating Controls AI
Per-CVE control mapping for this CVE has not run yet; the list below is derived from the weakness types (CWEs) cited in the NVD entry.