Cyber Resilience

CVE-2026-7694

Medium

Published: 03 May 2026

Published
03 May 2026
Modified
05 May 2026
KEV Added
Patch
CVSS Score v4 5.5 CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X
EPSS Score 0.0001 2.0th percentile
Risk Priority 11 60% EPSS · 20% KEV · 20% CVSS

Summary

CVE-2026-7694 is a medium-severity Injection (CWE-74) vulnerability in Feishu (inferred from references). Its CVSS base score is 5.5 (Medium).

Operationally, exploitation aligns with the MITRE ATT&CK technique Exploit Public-Facing Application (T1190); ranked at the 2.0th percentile by exploit likelihood (below the median); it is not currently listed in the CISA KEV catalog.

The strongest mitigations our analysis identified are NIST 800-53 SI-10 (Information Input Validation) and SI-2 (Flaw Remediation).

Deeper analysis

CVE-2026-7694 is a SQL injection vulnerability (CWE-74, CWE-89) in Acrel Electrical ECEMS Enterprise Microgrid Energy Efficiency Management System version 1.3.0. The issue resides in an unknown function of the file /SubstationWEBV2/main/elecMaxMinAvgValue, where manipulation of the fCircuitids argument triggers the injection.

The vulnerability is remotely exploitable by unauthenticated attackers with low attack complexity and no user interaction required, per its CVSS 3.1 score of 7.3 (AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L). Exploitation enables limited impacts on confidentiality, integrity, and availability through SQL injection.

Advisories indicate no vendor response despite early contact, with no patches or mitigations detailed. An exploit has been published and may be used, as documented in references including VulDB entries and a Feishu wiki.

Notable context includes the public availability of the exploit, increasing risk for exposed instances of this energy management system.

EU & UK References

Vulnerability details

A flaw has been found in Acrel Electrical ECEMS Enterprise Microgrid Energy Efficiency Management System 1.3.0. The impacted element is an unknown function of the file /SubstationWEBV2/main/elecMaxMinAvgValue. Executing a manipulation of the argument fCircuitids can lead to sql injection. The…

more

attack can be launched remotely. The exploit has been published and may be used. The vendor was contacted early about this disclosure but did not respond in any way.

CWE(s)

Related Threats

MITRE ATT&CK Enterprise TechniquesAI

T1190 Exploit Public-Facing Application Initial Access
Adversaries may attempt to exploit a weakness in an Internet-facing host or system to initially access a network.
Why these techniques?

Remote unauthenticated SQL injection in a public-facing web application endpoint directly enables initial access through exploitation of public-facing applications.

Confidence: HIGH · MITRE ATT&CK Enterprise v18.1

CVEs Like This One

CVE-2026-3150Shared CWE-74, CWE-89
CVE-2026-3746Shared CWE-74, CWE-89
CVE-2025-2683Shared CWE-74, CWE-89
CVE-2026-5238Shared CWE-74, CWE-89
CVE-2026-4288Shared CWE-74, CWE-89
CVE-2026-2220Shared CWE-74, CWE-89
CVE-2025-1535Shared CWE-74, CWE-89
CVE-2026-0597Shared CWE-74, CWE-89
CVE-2026-1688Shared CWE-74, CWE-89
CVE-2026-5018Shared CWE-74, CWE-89

Affected Assets

Feishu
inferred from references and description; NVD did not file a CPE for this CVE

Mitigating Controls

Mitigating Controls (NIST 800-53 r5) AI

prevent

SI-10 directly prevents SQL injection by requiring validation of untrusted inputs like the fCircuitids parameter before processing.

prevent

SI-2 mandates timely identification, reporting, and remediation of flaws such as this SQL injection vulnerability in the application.

detect

RA-5 enables vulnerability scanning to detect SQL injection issues like CVE-2026-7694 in exposed web endpoints.

References